A Quantitative Detection Algorithm for Multi-Test Line Lateral Flow Immunoassay Applied in Smartphones

نویسندگان

چکیده

The traditional lateral flow immunoassay (LFIA) detection method suffers from issues such as unstable results and low quantitative accuracy. In this study, we propose a novel multi-test line using smartphone-based SAA strips. Following the utilization of image processing techniques to extract analyze pigments on strips, analysis was conducted. Experimental setups with controlled lighting conditions in dark box were designed capture samples smartphones different specifications for analysis. algorithm’s sensitivity robustness validated by introducing noise samples, performance strips algorithms determined. experimental demonstrate that proposed based achieves an accuracy rate 94.23% 260 which is comparable methods but higher stability lower algorithm complexity.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of a quantitative lateral flow immunoassay for the detection of aflatoxins in maize.

An immunoassay-based lateral flow device for the quantitative determination of four major aflatoxins in maize has been developed. The one-step assay has performance comparably with that of other screening methods, as confirmed by the intra- and the inter-day precision of the data (RSD 10-22%), and can be completed in 10 min. Quantification was obtained by acquiring images of the strip and corre...

متن کامل

Lateral flow immunoassay for quantitative detection of ractopamine in swine urine.

A strip reader based lateral flow immunoassay (LFIA) was established for the rapid and quantitative detection of ractopamine (RAC) in swine urine. The ratio of the optical densities (ODs) of the test line (AT) to that of the control line (AC) was used to effectively minimize interference among strips and sample variations. The linear range for the quantitative detection of RAC was 0.2 ng/mL to ...

متن کامل

Development and Validation of a Lateral Flow Immunoassay Test Kit for Dual Detection of Casein and Î2-Lactoglobulin Residues

Allergies to cow’s milk are very common and can present as life-threatening anaphylaxis. Consequently, food labeling legislation mandates that foods containing milk residues, including casein and/or b-lactoglobulin, provide an indication of such on the product label. Because contamination with either component independent of the other can occur during food manufacturing, effective allergen mana...

متن کامل

A highly sensitive europium nanoparticle-based lateral flow immunoassay for detection of chloramphenicol residue.

A europium nanoparticle-based lateral flow immunoassay for highly sensitive detection of chloramphenicol residue was developed. The detection result could be either qualitatively resolved with naked eye or quantitatively analyzed with the assistance of a digital camera. In the qualitative mode, the limit of detection (LOD) was found to be 0.25 ng/mL. In the quantitative mode, the half-maximal i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Sensors

سال: 2023

ISSN: ['1424-8220']

DOI: https://doi.org/10.3390/s23146401