A prototype rapid dual energy X-ray absorptiometry (DEXA) system can predict the CT composition of beef carcases

نویسندگان

چکیده

The development of a novel rapid dual energy X-ray absorptiometry (DEXA) system provides the opportunity to improve measurement beef carcase composition. A prototype DEXA was built in shipping container scan 51 carcases selected for wide range weight and fatness. One side each spray chilled other conventionally overnight before being quartered scanning then cut into 16 pieces CT determine Spray chilling did not impact prediction composition, with describing 89%, 95%, 87% variation lean %, fat % bone root mean square error 2.31 2.15 1.12 units. These results demonstrate that has excellent capacity predict composition carcases.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Bone Mineral Density Measured by Dual X-ray, Axial Dual-energy Photon X-ray Absorptiometry and Laser Absorptiometry of Calcaneus

The objective of this study was to validate the use of bone mineral measurements of the calcaneus bone by dual X-ray and laser (DXL) in a cross-sectional study carried out in an osteoporosis clinic. Measurements of bone mineral density (BMD) at proximal femur and spine were obtained by dual-energy photon X-ray absorptiometry (DEXA). Osteoporosis was defined by a DEXA T-score <-2.5 at the femora...

متن کامل

Determination of the Precision of Dual Energy X-ray Absorptiometry (dexa) When Applied at the Knee

Introduction: Dual energy x-ray absorptiometry (DEXA) is one of the most widely used methods measuring periprosthetic bone mineral density (BMD). Several reports have presented the precision of DEXA when used at the hip, whereas similar reports on factors influencing the precision at the knee are sparse. There are two noticeable aspects when measuring BMD at the knee. First, no software specifi...

متن کامل

Dual-energy x-ray absorptiometry in obesity.

48 CMAJ, January 7, 2014, 186(1) © 2014 Canadian Medical Association or its licensors Two patients with grade III obesity (body mass index [BMI] ≥ 40), a 31-year-old man (A) and a 26-year-old woman (B), underwent Roux-en-Y gastric bypass on vertical banded gastroplasty. Both patients followed the same nutritional and postsurgical approach. After 12 months, both patients achieved a similar reduc...

متن کامل

Technical note: Prediction of chemical rib section composition by dual energy X-ray absorptiometry in Zebu beef cattle.

It is expensive and laborious to evaluate carcass composition in beef cattle. The objective of this study was to evaluate a method to predict the 9th to 11th rib section (rib) composition through empirical equations using dual energy X-ray absorptiometry (DXA). Dual energy X-ray absorptiometry is a validated method used to describe tissue composition in humans and other animals, but few studies...

متن کامل

comparison of bone mineral density measured by dual x-ray, axial dual-energy photon x-ray absorptiometry and laser absorptiometry of calcaneus

the objective of this study was to validate the use of bone mineral measurements of the calcaneus bone by dual x-ray and laser (dxl) in a cross-sectional study carried out in an osteoporosis clinic. measurements of bone mineral density (bmd) at proximal femur and spine were obtained by dual-energy photon x-ray absorptiometry (dexa). osteoporosis was defined by a dexa t-score <-2.5 at the femora...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Meat Science

سال: 2021

ISSN: ['0309-1740', '1873-4138']

DOI: https://doi.org/10.1016/j.meatsci.2020.108397