The presence of chemical warfare agents (CWAs) in the environment is a serious threat to human safety, but there are many problems with currently available detection methods for CWAs. For example, gas chromatography–mass spectrometry cannot be used in-field owing rather large size equipment required, while commercial sensors have disadvantages low sensitivity and poor selectivity. Here, we develop portable sensing instrument CWA that consists MEMS-fabricated micro-preconcentrator (μPC) film bulk acoustic resonator (FBAR) sensor. μPC coated nanoporous metal–organic framework material enrich target, FBAR provides rapid without need extra carrier gas. Dimethyl methylphosphonate (DMMP), simulant agent sarin, test performance instrument. Experimental results show effective sample pretreatment, sensor has good DMMP vapor. combination one gives full play their respective advantages, reducing limit analyte. Moreover, both fabricated using CMOS-compatible approach, prototype compact high portability thus potential application
منابع مشابه
Effects of Textural Properties on the Response of a SnO2-Based Gas Sensor for the Detection of Chemical Warfare Agents
The sensing behavior of SnO(2)-based thick film gas sensors in a flow system in the presence of a very low concentration (ppb level) of chemical agent simulants such as acetonitrile, dipropylene glycol methyl ether (DPGME), dimethyl methylphosphonate (DMMP), and dichloromethane (DCM) was investigated. Commercial SnO(2) [SnO(2)(C)] and nano-SnO(2) prepared by the precipitation method [SnO(2)(P)]...
متن کاملDesign, Fabrication, and Evaluation of Highly Sensitive Compact Chemical Sensor System Employing a Microcantilever Array and a Preconcentrator
We developed a highly sensitive compact chemical sensor system employing a polymer-coated microcantilever sensor array and a thermal preconcentrator. The design, structure, fabrication, and experiment results are reported here. This sensor system had 1) a sub-ppb detection limit concentrated by a preconcentrator and 2) analytical function by thermal desorption of the preconcentrator and multipl...