A prototype portable instrument employing micro-preconcentrator and FBAR sensor for the detection of chemical warfare agents

نویسندگان

چکیده

The presence of chemical warfare agents (CWAs) in the environment is a serious threat to human safety, but there are many problems with currently available detection methods for CWAs. For example, gas chromatography–mass spectrometry cannot be used in-field owing rather large size equipment required, while commercial sensors have disadvantages low sensitivity and poor selectivity. Here, we develop portable sensing instrument CWA that consists MEMS-fabricated micro-preconcentrator (μPC) film bulk acoustic resonator (FBAR) sensor. μPC coated nanoporous metal–organic framework material enrich target, FBAR provides rapid without need extra carrier gas. Dimethyl methylphosphonate (DMMP), simulant agent sarin, test performance instrument. Experimental results show effective sample pretreatment, sensor has good DMMP vapor. combination one gives full play their respective advantages, reducing limit analyte. Moreover, both fabricated using CMOS-compatible approach, prototype compact high portability thus potential application

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of Textural Properties on the Response of a SnO2-Based Gas Sensor for the Detection of Chemical Warfare Agents

The sensing behavior of SnO(2)-based thick film gas sensors in a flow system in the presence of a very low concentration (ppb level) of chemical agent simulants such as acetonitrile, dipropylene glycol methyl ether (DPGME), dimethyl methylphosphonate (DMMP), and dichloromethane (DCM) was investigated. Commercial SnO(2) [SnO(2)(C)] and nano-SnO(2) prepared by the precipitation method [SnO(2)(P)]...

متن کامل

Design, Fabrication, and Evaluation of Highly Sensitive Compact Chemical Sensor System Employing a Microcantilever Array and a Preconcentrator

We developed a highly sensitive compact chemical sensor system employing a polymer-coated microcantilever sensor array and a thermal preconcentrator. The design, structure, fabrication, and experiment results are reported here. This sensor system had 1) a sub-ppb detection limit concentrated by a preconcentrator and 2) analytical function by thermal desorption of the preconcentrator and multipl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Nanotechnology and Precision Engineering

سال: 2022

ISSN: ['2589-5540', '1672-6030']