A Proposed Four-element Neutron-photon-beta Thermoluminescence Dosimeter
نویسندگان
چکیده
منابع مشابه
A Novel Neutron Dosimeter
Background: Neutron contamination in our environment can cause harmful biological effects on human body. Therefore, many efforts have been made to construct a neutron dosimeter to estimate the received dose. Objective: To design a simple neutron dosimeter. Methods: The primary dosimeter had 3He as a spherical thermal neutron detector encircled by paraffin 10 cm in radius. Then, the paraffin sph...
متن کاملa novel neutron dosimeter
background: neutron contamination in our environment can cause harmful biological effects on human body. therefore, many efforts have been made to construct a neutron dosimeter to estimate the received dose. objective: to design a simple neutron dosimeter. methods: the primary dosimeter had 3he as a spherical thermal neutron detector encircled by paraffin 10 cm in radius. then, the paraffin sph...
متن کاملProposed Measurement of the Beta-Neutrino Correlation in Neutron Decay
Currently, the beta-neutrino asymmetry has the largest uncertainty (4 %) of the neutron decay angular correlations. Without requiring polarimetry this decay parameter can be used to measure λ (ga/gv ), test Cabibbo-Kobayashi-Maskawa (CKM) unitarity limit scalar and tensor currents, and search for Charged Vector Current (CVC) violation. We propose to measure the beta-neutrino asymmetry coeffcien...
متن کاملInvestigation of neutron flux by thermoluminescence dosimeters in the neutron-gamma mixed field
Introduction: Neutrons have many applications in various fields, such as medicine. The important application of neutron in medical science is in Boron Neutron Capture Therapy (BNCT). Because of this, determination of neutron dose and flux is critical for the health maintaining of workers and patients exposed to this beam. The neutron radioisotope sources produce gamma rays in ...
متن کاملA Proposed Modeling Method in Finite Element Slope Stability Analysis
Limit-equilibrium method (LEM) and finite element method (FEM) with strength reduction method (SRM) techniques are the most widely used analysis tools in slope stability assessment. Recently, researchers have reported that both factor of safety (FOS) values and failure surfaces obtained from LEM and FEM are generally in good agreement, except in some particular cases. In this paper, the FOS and...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Health Physics
سال: 1992
ISSN: 0017-9078