A PRELIMINARY STUDY OF RADIATION QUALITY CORRECTION FACTOR (KQ) DETERMINATION FOR WELL-TYPE IONIZATION CHAMBER
نویسندگان
چکیده
منابع مشابه
Evaluation of dosimetry a performance parameter for a homemade farmer-type ionization chamber according to IEC60731
Introduction: Due to its simplicity, fast response and high reliability, ion chamber detectors are one of the most suitable dosimetry instruments for X and gamma rays. The dosimeter of photon beams, which used in radiotherapy centers, requires high accuracy and should pass requirements of IEC 60731 standards. About 80 percent of the IEC 60731 standard tests such as stabil...
متن کاملthe investigation of the relationship between type a and type b personalities and quality of translation
چکیده ندارد.
Design and fabrication of cylindrical ionization chamber for application in radiation protection
According to International Atomic Energy Agency (IAEA) recommendations, the calibration of ionization chambers used for radiotherapy dosimetry follows the substitution method which demands the use of a reference ionization chamber. This work introduces the Design and fabrication of cylindrical ionization chamber for dosimetry to be used by standard dosimetry laboratories. The result of the qual...
متن کاملFabrication of Free Air Well Type Ionization Chamber and Calculational Assessment and Measurement of Its Operational Characteristics
Introduction: Well type ionization chamber is a measuring device which is used to determine the activity of brachytherapy sources. The chamber has a cylindrical volume in which a cylindrical tube is mounted in the middle of the chamber. For the measurements, the brachytherapy sources are transferred to the middle of the tube. Materials and Methods: For designing the well type chamber, the measu...
متن کاملMonte Carlo calculations of beam quality correction factors kQ for electron dosimetry with a parallel-plate Roos chamber.
Current dosimetry protocols (AAPM, IAEA, DIN) recommend the use of parallel-plate ionization chambers for the measurement of absorbed dose-to-water in clinical electron beams. For well-guarded plane-parallel chambers, it is assumed that the perturbation correction pQ is unity for all electron energies. In this study, we present detailed Monte Carlo simulations with the EGSnrc code for the widel...