A possibility of transverse beam size diagnostics using parametric X-ray radiation
نویسندگان
چکیده
منابع مشابه
Bunch Coherence in Parametric X-ray Radiation
The amplitude of Parametric X-ray radiation emitted coherently by a bunch of electrons crossing a crystal (CPXR) is calculated. When the bunch density is modulated with a longitudinal period close to the X-ray wavelenght, constructive many-electron interferences enhance the intensity by Nb × |F (K)| , where Nb is the number of electrons in the bunch, F (K) the bunch form factor and K a specifie...
متن کاملTransverse Coherence P Roperties of the Lcls X-ray Beam∗
Self-amplifying spontaneous radiation free-electron lasers, such as the LCLS or the European X-FEL, rely on the incoherent, spontaneous radiation as the seed for the amplifying process. Though this method overcomes the need for an external seed source one drawback is the incoherence of the effective seed signal. The FEL process allows for a natural growth of the coherence because the radiation ...
متن کاملInfluence of Beam Divergence and Crystal Mosaic Structure upon Parametric X-ray Radiation Characteristics
Based on kinematic model of parametric X-ray radiation (PXR), an approach for calculation of PXR characteristics (spectrum, intensity, polarization and yield) has been developed. The approach allows to take into account the beam divergence, mosaicity, aperture sizes, influence of K-edge, etc. using a uniform technique. 1. The existing theoretical models [1-3] describe the process of parametricX...
متن کاملReal-time in-situ X-ray beam diagnostics
We report on a novel diagnostics instrument for in-situ imaging and measurements of X-ray beam parameters in real-time. The instrument is based on the robust and simple idea of a pinhole camera that collects the weakly scattered radiation from a thin sheet of a low-Z material placed in the X-ray beam at an acute angle. We demonstrate how by recording the scattered radiation with an appropriate ...
متن کاملmonte carlo simulation of a 6 mv x-ray beam for open and wedge radiation fields, using gate code
the aim of this study is to provide a control software system, based on monte carlo simulation, and calculations of dosimetric parameters of standard and wedge radiation fi elds, using a monte carlo method. gate version 6.1 (opengate collaboration), was used to simulate a compact 6 mv linear accelerator system. in order to accelerate the calculations, the phase-space technique and cluster compu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Physics: Conference Series
سال: 2012
ISSN: 1742-6596
DOI: 10.1088/1742-6596/357/1/012018