A portable gamma-ray spectrometer using compressed xenon
نویسندگان
چکیده
منابع مشابه
A high pressure xenon gamma-ray spectrometer using a coplanar anode configuration
A new design of a high pressure xenon ionization chamber has been fabricated in an attempt to eliminate the problems associated with acoustical vibrations of the Frisch grid. The function of the traditional Frisch grid has been accomplished by employing a coplanar anode system capable of single polarity charge sensing. Two different detector designs have been fabricated using both cylindrical a...
متن کاملTransient Gamma-Ray Spectrometer
Visible afterglow counterparts have now been detected for two GRBs (970228 and 970508) but are absent, with Lopt/Lγ ratios at least two orders of magnitude lower, for other GRBs, e.g., 970828. The causes of this variation are unknown. Any correspondence which could be discovered between the γ-ray properties of a GRB and its Lopt/Lγ would be useful, both in determining the GRB mechanisms, and in...
متن کاملThe NEAR X-Ray/Gamma-Ray Spectrometer
he X-Ray/Gamma-Ray Spectrometer on the Near Earth Asteroid Rendezvous (NEAR) spacecraft will remotely sense X-ray and gamma-ray emissions from the surface of near-Earth asteroid 433 Eros and look for characteristic “signatures” in those emissions to determine its elemental composition. During the planned 10 months of orbits about Eros beginning in early 1999, data returned from the instrument w...
متن کاملCdZnTe Gamma Ray Spectrometer for Orbital Gamma Ray Spectroscopy
We present the design and analysis of a new gamma ray spectrometer for planetary science that uses an array of CdZnTe detectors to achieve the detection efficiency needed for orbital measurements. The use of CdZnTe will provide significantly improved pulse height resolution relative to scintillation-based detectors, with commensurate improvement in the accuracy of elemental abundances determine...
متن کاملFormation interface detection using Gamma Ray log: A novel approach
There are two methods for identifying formation interface in oil wells: core analysis, which is a precise approach but costly and time consuming, and well logs analysis, which petrophysists perform, which is subjective and not completely reliable. In this paper, a novel coupled method was proposed to detect the formation interfaces using GR logs. Second approximation level (a2) of GR log gained...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Nuclear Science
سال: 1998
ISSN: 0018-9499,1558-1578
DOI: 10.1109/23.682701