A Polystyrene-Water Calorimeter
The paper describes a new type of calorimeter that can be quickly put into operation for determining absorbed dose at a point in polystyrene. It also describes a unique method of decreasing drifts in electrical signals caused by temperature gradients. Two calibrated thermistors were placed close together between sandwiched polystyrene discs that were immersed in water. The assembly was irradiat...
متن کاملA Study of the Water Cherenkov Calorimeter
The novel idea of water Cherenkov calorimeter made of water tanks as the next generation neutrino detector for ν factories and ν beams is investigated. A water tank prototype with a dimension of 1×1×13m is constructed, its performance is studied and compared with a GEANT4 based Monte Carlo simulation. By using measured parameters of the water tank, including the light collection efficiency, att...
متن کاملA Sealed Water Calorimeter for Measuring Absorbed Dose
National Institute of Standards and Technology, Gaithersburg, MD 20899-0001 The NIST sealed water calorimeter is intended for direct measurement of absorbed dose to water. This calorimeter was used for a series of approximately 3700 measurements to investigate the so-called heat defect, that is, anomalous endothermic or exothermic effects caused by dissolved gases. The three systems investigate...
متن کاملA Water Čerenkov Calorimeter as the Next Generation Neutrino Detector
We propose here a large homogeneous calorimeter as the next generation neutrino detector for ν factories and/or conventional ν beams. The active media is chosen to be water for obvious economical reasons. The Čerenkov light produced in water is sufficient to have good energy resolution, and the pattern recognition is realized by a modular water tank structure. Monte Carlo simulations demonstrat...
متن کاملStudies of Excess Heat and Convection in a Water Calorimeter
To explain a difference of 0.5 % between the absorbed-dose standards of the National Institute of Standards and Technology (NIST) and the National Research Council of Canada (NRCC), Seuntjens et al. suggest the fault lies with the NIST water calorimeter being operated at 22 °C and the method with which the measurements were made. Their calculations show that this difference is due to overpredic...