A Plastic Scintillator Based on an Efficient Thermally Activated Delayed Fluorescence Emitter 9‐(4‐(4,6‐diphenyl‐1,3,5‐triazin‐2‐yl)‐2‐methylphenyl)‐3,6‐dioctyl‐9 <i>H</i> ‐carbazole for Pulse Shape Discrimination Measurement

نویسندگان

چکیده

Pulse shape discrimination (PSD)-capable plastic scintillator is in demand for the detection of high-energy neutrons presence gamma radiation background. Conventional PSD plastics are based on delayed fluorescent dye via triplet–triplet annihilation a additive, which inefficient to harvest energy triplet excitons. In recent years, thermally activated fluorescence (TADF) emitters have gained substantial success organic light-emitting diodes due their efficient utilization excitons and thereby achieving theoretical unity internal quantum efficiencies. Herein, highly TADF 9-(4-(4,6-diphenyl-1,3,5-triazin-2-yl)-2-methylphenyl)-3,6-dioctyl-9H-carbazole reported application. This may be loaded up 30 wt% polyvinyltoluene matrix still retains high optical transparency. High scintillation light yield figures merit obtained from plastic. With introduction secondary further increase efficiency excitation energy, increased 6948 photons MeV−1. The measured alpha/gamma figure 1.12 at threshold 100 keVee neutron/gamma 1.32 1000 keVee.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A versatile thermally activated delayed fluorescence emitter for both highly efficient doped and non-doped organic light emitting devices.

A thermally activated delayed fluorescent (TADF) emitter (DMAC-TRZ) was reported either as the emitting dopant in a host or as the non-doped (neat) emitting layer to achieve high EL EQEs of up to 26.5% and 20% in OLEDs, respectively.

متن کامل

Neutron generator burst timing measured using a pulse shape discrimination plastic scintillator with silicon photomultiplier readout

An EJ-299-34 plastic scintillator with silicon photomultiplier (SiPM) readout was used to measure the fast neutron output of a pulsed Thermo-Fisher A-325 Deuterium-Tritium sealed tube neutron generator (STNG). The SiPM signals were handled by a prototype digital pulse processing system, based on a free-running analogue to digital converter feeding a digital signal processor (DSP). Pulse shape d...

متن کامل

Comparative analysis of pulse shape discrimination methods in a Li loaded plastic scintillator

Three algorithms for discriminating between fast neutrons, thermal neutrons and gamma rays in a Li loaded plastic scintillator have been compared. Following a literature review of existing pulse shape discrimination techniques, the performance of the charge comparison method, triangular filtering and frequency gradient analysis were investigated in this work. The scintillator was exposed to thr...

متن کامل

Thermally activated delayed fluorescence in fullerenes.

This report reviews the thermally activated delayed fluorescence (TADF) displayed by fullerenes. From the analysis of the steady-state data, time-resolved data, or by a combination of both, it is possible to determine several important photophysical parameters of fullerenes. Herein we also cover the development of temperature and oxygen sensors based on the TADF effect exhibited by fullerene C(...

متن کامل

Photophysics of thermally activated delayed fluorescence molecules.

Thermally activated delayed fluorescence (TADF) has recently emerged as one of the most attractive methods for harvesting triplet states in metal-free organic materials for application in organic light emitting diodes (OLEDs). A large number of TADF molecules have been reported in the literature with the purpose of enhancing the efficiency of OLEDs by converting non-emissive triplet states into...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Advanced Optical Materials

سال: 2021

ISSN: ['2195-1071']

DOI: https://doi.org/10.1002/adom.202001975