A Phasor-Data-Based State Estimator Incorporating Phase Bias Correction
نویسندگان
چکیده
منابع مشابه
Synchronized Phasor Measurements in a Dual Layer Hybrid State Estimator
Original scientific paper The architecture of the proposed Dual Layer Hybrid State Estimator starts with the linear state estimator that only takes synchrophasors as inputs and calculates states of the buses with the deployed Phasor Measurement Units (PMUs) and their adjacent buses. These states are used to obtain the pseudomeasurements that are processed together with conventional SCADA measur...
متن کاملA Voltage Phasor Based Fault Classification Method for PMU Only State Estimator Output
This paper presents a fault classification method for transmission lines based on voltage phasors using classification and regression trees (CART). The proposed method is intended to aid system operators in understanding the outputs of a PMU only state estimator. Faults are classified into four categories when the estimator is positive sequence and into ten categories when the estimator is thre...
متن کاملA comparative study of quantitative mapping methods for bias correction of ERA5 reanalysis precipitation data
This study evaluates the ability of different quantitative mapping (QM) methods as a bias correction technique for ERA5 reanalysis precipitation data. Climate type and geographical location can affect the performance of the bias correction method due to differences in precipitation characteristics. For this purpose, ERA5 reanalysis precipitation data for the years 1989-2019 for 10 selected syno...
متن کاملFast Initial State Assessment for State Estimator using Optimally Located Phasor Measurement Units
Complex power systems need better observability and visualization capabilities to handle critical situations effectively. Synchro-phasor measurements provide intra second visibility to power system dynamics and enable faster control actions. A Phasor Measurement Unit (PMU) measures the voltage and current phasors (angle and magnitude) at a bus in a power system. In the literature, many methods ...
متن کاملA Quaternion Frequency and Phasor Estimator for Three-Phase Power Distribution Networks
The multi-dimensional nature of quaternions allows for the full characterization of three-phase power systems. This is achieved through the use of quaternions to provide a unified framework for incorporating voltage measurements from all the phases of a three-phase system and then employing the recently introduced HR-calculus to derive a state space estimator based on the quaternion extended Ka...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Power Systems
سال: 2011
ISSN: 0885-8950,1558-0679
DOI: 10.1109/tpwrs.2010.2047031