A Novel Vitreous Substitute of Using a Foldable Capsular Vitreous Body Injected with Polyvinylalcohol Hydrogel
نویسندگان
چکیده
منابع مشابه
A Novel Vitreous Substitute of Using a Foldable Capsular Vitreous Body Injected with Polyvinylalcohol Hydrogel
Hydrogels may be the ideal vitreous substitutes due to their wonderful physical features and biocompatibility. However, their drawbacks, short residence time, and biodegradation in vivo, have led to the fact that none of them have been approved for clinical use. In this study, we developed a novel approach of using a foldable capsular vitreous body (FCVB) injected with polyvinylalcohol (PVA) hy...
متن کاملA Novel Artificial Vitreous Substitute – Foldable Capsular Vitreous Body
The natural vitreous is a transparent, gelatinoid structure occupying four-fifths of the volume of the eye. It has a thin, membrane-like structure corresponding to the vitreous cortex that extends from the ora serrata to the posterior pole.1 It is somewhat spherical but slightly flattened meridionally, and it has a cup-shaped depression in its anterior side. It consists of about 99% water by we...
متن کاملEvaluation of the levofloxacin release characters from a rabbit foldable capsular vitreous body
The authors have manufactured a novel rabbit foldable capsular vitreous body (FCVB). The aim of this study was to determine whether this rabbit FCVB can release levofloxacin in vitro and in vivo, and to evaluate the release characteristics. In vitro, the rabbit FCVB with levofloxacin 500 μg/mL was immersed in cups of modified Franz diffusion cells. Following this, 200 μL of liquid was aspirated...
متن کاملRabbit study of an in situ forming hydrogel vitreous substitute.
PURPOSE An in situ forming hydrogel was evaluated as a potential vitreous substitute in rabbits. METHODS The hydrogel used a disulfide cross-linker that was then reduced to produce an injectable thiol-containing polymer solution. The disulfide cross-links reformed by air oxidation of the thiols and produced a stable hydrogel once inside the eye. The polymer was clear, autoclavable, and could ...
متن کاملEvaluation of the flexibility, efficacy, and safety of a foldable capsular vitreous body in the treatment of severe retinal detachment.
PURPOSE To determine the flexibility, efficacy, and safety of a novel foldable capsular vitreous body (FCVB) in the treatment of severe retinal detachment in human eyes. METHODS The study involved 11 patients with 11 severe retinal detachments. A standard three-port pars plana vitrectomy was performed, and the FCVB was triple-folded and implanted into the vitreous cavity. Balanced salt soluti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Scientific Reports
سال: 2013
ISSN: 2045-2322
DOI: 10.1038/srep01838