A novel variable force ratio test system for force measurement
نویسندگان
چکیده
منابع مشابه
Weak Force Measurement in Bistable Optomechanical System
One of the main milestones in the study of opto-mechanical system is to increase the sensitivity of weak forces measurement up to the standard quantum limit. We have studied the detection of weak force under a bistable condition in red detuned regime. In this case, dynamics of the system behaves asymptotically similar to stationary state and applying external force affects phase and fluctuation...
متن کاملForce-torque Measurement System for Fracture Surgery
Many surgical procedures are now performed using the techniques of minimally invasive surgery (MIS), in which the surgeon manipulates instruments inserted into the patients through small incisions. In MIS, the surgeon has no direct contact with internal body parts. Applying an optimal force and torque via the instruments is necessary to conduct an operation without causing any damage to the int...
متن کاملDesign and Test of a Soft Plantar Force Measurement System for Gait Detection
This work describes a plantar force measurement system. The MEMS pressure sensor, as the key sensing element, is designed, fabricated and embedded into a flexible silicon oil-filled bladder made of silicon rubber to constitute a single sensing unit. A conditioning circuit is designed for signal processing and data acquisition. The characteristics of the plantar force sensing unit are investigat...
متن کاملMeasurement of Poisson’s ratio with contact- resonance atomic force microscopy
We describe contact-resonance atomic force microscopy ͑AFM͒ methods to quantitatively measure Poisson's ratio or shear modulus G at the same time as Young's modulus E. In contact-resonance AFM, the frequencies of the cantilever's resonant vibrations are measured while the tip is in contact with the sample. Simultaneous measurement of flexural and torsional vibrational modes enables E and to b...
متن کاملStatic Absolute Force Measurement for Preloaded Piezoelements Used for Active Lorentz Force Detuning System
To reach high gradients in pulsed operation of superconducting (SC) cavities an active Lorentz force detuning compensation system is needed. For this system a piezoelement can be used as an actuator (other option is a magnetostrictive device). To guarantee the demanded lifetime of the active element, the proper preload force adjustment is necessary. To determine this parameter an absolute force...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Advances in Mechanical Engineering
سال: 2019
ISSN: 1687-8140,1687-8140
DOI: 10.1177/1687814019832086