A novel self-expanding biflanged metal stent vs tubular metal stent for EUS-guided transmural drainage of pancreatic pseudocyst
نویسندگان
چکیده
منابع مشابه
Bleeding Risk of Stent Removal After EUS-Guided Cystgastrostomy and Metal Stent Placement for Drainage of a Pancreatic Fluid Collection
Endoscopists are keenly aware of bleeding risks during and immediately after cystgastrostomy and reduce this risk by endoscopic ultrasound guidance to avoid manipulation near major vessels. Bleeding risk associated with cystgastrostomy stent removal after resolution of a pancreatic fluid collection, however, is less evident. We present our experience with bleeding during cystgastrostomy stent r...
متن کاملArterial bleeding during EUS-guided pseudocyst drainage stopped by placement of a covered self-expandable metal stent
BACKGROUND Hemorrhagic complications during EUS-guided pseudocyst drainage can occur, because the vessels on the internal wall of the pseudocyst might be compressed by the fluid and thus not visible on color Doppler or even power Doppler EUS. CASE PRESENTATION We report a case of an immediate internal spurting arterial bleeding precipitated during EUS-guided pseudocyst drainage which stopped ...
متن کاملEndoscopic ultrasound-guided transesophageal drainage of a mediastinal pancreatic pseudocyst using a novel lumen-apposing metal stent.
There have been a few previous reports of transesophageal endoscopic ultrasound (EUS)-guided drainage of pancreatic fluid collections (PFC). In these reports the drainage modality has been a single aspiration or deployment of a plastic stent [1–4]. We report a patient who underwent transesophageal EUS-guided drainage of a mediastinal PFC using a novel lumen-apposing metal stent. A 37-year-old m...
متن کاملSalvaging a malpositioned fully covered self-expanding metal stent for pancreatic fluid collection drainage.
A 44-year-old man presentedwith a large, symptomatic pancreatic fluid collection (PFC) 6 weeks after an episode of alcoholrelated acute necrotizing pancreatitis. Imaging confirmed an area of walled-off necrosis (WON) measuring 15×12mm and containing solid debris. He underwent endoscopic ultrasound (EUS)-guided drainage with the aim of placing a dedicated fully covered self-expanding metal stent...
متن کاملEUS-guided gall bladder drainage with a lumen-apposing metal stent: a prospective long-term evaluation.
Department of Gastroenterology and Hepatology, University Medical Center Utrecht, Utrecht, The Netherlands Department of Surgery, Chinese University of Hong Kong, Prince of Wales Hospital, Hong Kong, Hong Kong Department of Gastroenterology and Hepatology, Tokyo Medical University, Tokyo, Japan Department of Gastroenterology and Hepatology, University Hospital Rio Hortega, Valladolid, Spain Dig...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Medicine
سال: 2019
ISSN: 0025-7974,1536-5964
DOI: 10.1097/md.0000000000014179