A novel precast concrete beam-to-column connection with replaceable energy-dissipation connector: Experimental investigation and theoretical analysis

نویسندگان

چکیده

To avoid the damage of connection due to overstrength beam strength, and alternation strength hierarchy in structural system, a novel precast concrete beam-to-column is proposed herein. In connection, replaceable energy-dissipation connector (REDC) was placed at bottom hidden corbel. addition, narrow vertical slot adjacent corbel reduce overstrength. First, features mechanical mechanism were discussed. Second, three low-cycle quasi-static loading tests carried out on single full-scaled specimen by using REDCs different sizes. The test results showed that seismic performance this excellent additional bending moment caused significantly lower than conventional connection. Third, finite element models developed further analyze how always keep top reinforcements elastic range. Finally, relevant design suggestions provided. designed according formulas can be minimized. view this, moments regarded as controllable variable.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance of the Modified Precast Beam to Column Connection Placed on a Concrete Corbel

Precast concrete structures in Iran are generally designed as continuous columns with hinged beams, thereby making them simple frames. In this system in site show walls in two directions of buildings guaranteed lateral resisting system. However, in order to obtain a seismic resisting frame, the connection between beam and column should be moment resisting and ductile, allowing the formation of ...

متن کامل

Finite element analysis of a rigid beam to column connection reinforced with channels

Abstract: This research work presents a new rigid connection constructed with channels. In order to assess its hysteresis behavior, three specimens with different cover plates and six specimens with different panel zone thickness have been considered. The energy absorbed by the connection and the behavior of the panel zone were studied during cyclic loading and compared with those of connectio...

متن کامل

Seismic behavior of semi-dry precast concrete connections using tapered thread couplers

The worldwide use of precast concrete frames leads to an increase in the need for the investigation of efficient precast connections, particularly in the seismic regions. The current paper provides a numerical and experimental study on a dry precast connection. Experiments were conducted to validate the finite element method in the laboratory of the University of Science and Culture. To verify ...

متن کامل

performance of exterior precast concrete beam-column dowel connections under cyclic loading

the present study focuses on the performance of precast concrete beam-column dowel connections subjected to cyclic loading by conducting experiments. in this study, one-third scale model of two types of precast and a monolithic beam-column connection were cast and tested under reverse cyclic loading. the precast connections considered for this study is a beam-column connection where beam is con...

متن کامل

Analytical and Experimental Investigation of I Beam-to-CFT Column Connections under Monotonic Loading (RESEARCH NOTE)

In this study, the behavior characteristics of I beam-to-concrete filled tube (CFT) column connection is studied through experiment and finite element models under the monotonic loading. To validate the finite element modeling, at first, an experimental model is made and experimented. After validation of the finite element modeling, different models were created in the software. The studied par...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Bulletin of Earthquake Engineering

سال: 2021

ISSN: ['1573-1456', '1570-761X']