A Novel Potentiometric Sensor for Determination of Neurotoxin β-N-Oxalyl-L-α, β-Diaminopropionic Acid

A novel potentiometric sensor based on ionophore (Cd(NH2CH2CH2OCH2CH2OCH2CH2NH2)Ag3(CN)5) for the determination of β-N-oxalyl-L-α, β-diaminopropionic acid (ODAP) is developed. The ODAP-selective membrane sensor demonstrates high sensitivity and short response time. The detection limit of the ODAP-selective membrane sensor is about 2 × 10(-6) mol L (-1) and the response time is shorter than 6 s....

متن کامل

Action of the neurotoxin -N-oxalyl-L- , -diaminopropionic acid on glutamate metabolism of brain mitochondria.

Mammalian neurolathyrism is a progressive and degenerative disease of central nervous system originating from excessive consumption of Lafhyrus seeds, particularly those of L. sativus. Rao et al. [I] have isolated P-N-oxalyl-L-a&diaminopropionic acid (ODAP) from the seeds of L. satiuus and shown this substance to be the neurotoxin [ 1, 21 Characterization of the biochemical effect and cellular ...

متن کامل

Performance Evaluation of a Novel Potentiometric Membrane Sensor for Determination of Atorvastatin in Pharmaceutical Preparations

A novel potentiometric ion-selective PVC membrane sensor for analysis of atorvastatin (AT) in pharmaceutical preparations based on atorvastatin-(tetraphenyl borate), (AT-(TPB)2) as sensing element, tetraphenyl borate as additive and tris-2-ethyl-hexyl phosphate (TOP) as plasticizer solvent was prepared. The electrode shows a good Nernestian response over the concentration range of 0.09–5586 µ...

متن کامل

Performance Evaluation of a Novel Potentiometric Membrane Sensor for Determination of Atorvastatin in Pharmaceutical Preparations

A novel potentiometric ion-selective PVC membrane sensor for analysis of atorvastatin (AT) in pharmaceutical preparations based on atorvastatin-(tetraphenyl borate), (AT-(TPB)2) as sensing element, tetraphenyl borate as additive and tris-2-ethyl-hexyl phosphate (TOP) as plasticizer solvent was prepared. The electrode shows a good Nernestian response over the concentration range of 0.09–5586 µ...

متن کامل

COBALT PHTHALOCYANINE MODIFIED CARBON PASTE ELECTRODE AS A POTENTIOMETRIC SENSOR FOR DETERMINATION OF ASCORBIC ACID

A carbon Paste electrode modified with cobalt (II) phthalocyanine (CoPC) was used as a sensitive potentiometric sensor for determination of ascorbic acid in aqueous solutions. The potential response of the electrode is a linear function of ascorbic acid concentration over the range 5 10 to 10 M (?1- 1800 µg ML ) with a Nernstian slope of 56 mV at pH 7. The limit of detection was 0.2 µg ...