A novel compensation method for Zirconium dioxide gated Ion Sensitive Field Effect Transistors (ISFETs) to improve pH-dependent drift was demonstrated. Through the sequential measurements for both the n-channel and p-channel ISFETs, 75-100% pH-dependent drift could be successfully suppressed for the first seven hours. As a result, a nearly constant drift rate versus pH value was obtained, which...

متن کامل

Ion-sensitive field effect transistor as a pH sensor.

In this work, both the static and dynamic behaviors as well as the signal read-out circuits of ISFETs were studied. The standard NMOS structure in conjunction with the insulator-electrolyte capacitor was used to model the ISFET under study. The site-binding theory was incorporated to describe the chemistry occurring at the insulator/electrolyte interface. The mechanism of the threshold voltage ...

متن کامل

Biocompatibility research of a novel pH sensitive ion exchange resin microsphere

The main objective of this study was to investigate biocompatibility and provide in vivo pharmacological and toxicological evidence for further investigation of the possibility of pH sensitive ion exchange resin microsphere for clinical utilizations. Acute toxicity study and general pharmacological studies were conducted on the pH sensitive ion exchange resin microsphere we prepared. The genera...

متن کامل

Biocompatibility research of a novel pH sensitive ion exchange resin microsphere

The main objective of this study was to investigate biocompatibility and provide in vivo pharmacological and toxicological evidence for further investigation of the possibility of pH sensitive ion exchange resin microsphere for clinical utilizations. Acute toxicity study and general pharmacological studies were conducted on the pH sensitive ion exchange resin microsphere we prepared. The genera...

متن کامل

fabrication of new ion sensitive field effect transistors (isfet) based on modification of junction-fet for analysis of hydronium, potassium and hydrazinium ions

a novel and ultra low cost isfet electrode and measurement system was designed for isfet application and detection of hydronium, hydrazinium and potassium ions. also, a measuring setup containing appropriate circuits, suitable analyzer (advantech board), de noise reduction elements, cooling system and pc was used for controlling the isfet electrode and various characteristic measurements. the t...

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Sensors

سال: 2010

ISSN: 1424-8220

DOI: 10.3390/s100504643