A novel multi-cell silicon drift detector for Low Energy X-Ray Fluorescence (LEXRF) spectroscopy

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Silicon Lithium Detectors for Synchrotron Energy Dispersive X-Ray Fluorescence Spectroscopy

Introduction Detector description and its principle of operation Detector module. Detector Features and its Performance EDXRF of Fe 55 Spectrum Detector comparison with Silicon Drift Detector SDD Concluding remarks References A Silicon Lithium Si(Li) detector is presented. The detector structure and its working principle are explained. The detector is cooled to 77o K by liquid Nitrogen. The det...

متن کامل

Partial Fluorescence Yield XAFS Measurements in Soft X-ray Region Using a Large-Area Silicon Drift Detector

X-ray absorption fine structure (XAFS) spectra in the soft X-ray region are obtained in the electron and fluorescence yield modes, which are sensitive to surface and bulk, respectively. A micro-channel plate (MCP) can be used as the detector for the total fluorescence yield (TFY) method by applying a sufficiently high negative bias to a grid in front of the MCP. However, this method often suffe...

متن کامل

Compton scattering artifacts in electron excited X-ray spectra measured with a silicon drift detector.

Artifacts are the nemesis of trace element analysis in electron-excited energy dispersive X-ray spectrometry. Peaks that result from nonideal behavior in the detector or sample can fool even an experienced microanalyst into believing that they have trace amounts of an element that is not present. Many artifacts, such as the Si escape peak, absorption edges, and coincidence peaks, can be traced ...

متن کامل

Determining the Content of Silicon Dioxide in Bauxites Using X-Ray Fluorescence Spectrometry

The X-ray fluorescence spectrometry and the MA.BM.006 reference spectrophotometric methods were used to determine the content of SiO2 (%) in bauxites from different deposits. The treatment of samples prior to the analysis involved the following steps: annealing, melting using the borax method,  and the formation of beads. Certified reference bauxite samples were used for the cali...

متن کامل

The new X-ray mapping: X-ray spectrum imaging above 100 kHz output count rate with the silicon drift detector.

Electron-excited X-ray mapping is a key operational mode of the scanning electron microscope (SEM) equipped with energy dispersive X-ray spectrometry (EDS). The popularity of X-ray mapping persists despite the significant time penalty due to the relatively low output count rates, typically less than 25 kHz, that can be processed with the conventional EDS. The silicon drift detector (SDD) uses t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Instrumentation

سال: 2014

ISSN: 1748-0221

DOI: 10.1088/1748-0221/9/12/c12017