A novel methodology for high‐frequency lumped equivalent circuit of an isolated transformer winding construction based on frequency response analysis signal morphology interpretation

نویسندگان

چکیده

A novel auto-synthesis method is proposed to construct the mutually coupled equivalent circuit of an isolated air-core transformer winding based on signal morphology interpretation its measured frequency response analysis (FRA) only. Therefore, this approach aims determine model parameters from sub-bands (low, medium and high frequency), each which reflects dominant parameters, where parameter identification procedure done their corresponding sub-band separately. Besides, optimisation algorithms have difficulties in estimating nearly unique lumped a large search space. For reason, analytical simplifications, two dynamic autonomous methods been restrict space bounds inductances capacitances. Finally, real case studies were used actual windings validate ability perform automated synthesis. Consequently, has accomplished automatically with accuracy.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transfer Function of Transformer Winding for Frequency Response Analysis Based on Traveling Wave Theory

This paper presents an improved model of uniform transformer winding for frequency response analysis (FRA), based on traveling wave theory. The accurate representation of the losses and detailed consideration of measurement chains are the main features of the model. The transfer function expression of the transformer winding and equivalent distributed-parameter circuit for FRA have been derived...

متن کامل

Efficiency Improvement of the Flyback Converter Based on High Frequency Transformer Winding Rearrangement

In this paper, a novel method for loss reduction and efficiency optimization of the high frequency flyback transformers is proposed based on rearrangement of the windings. According to detailed analysis of the high frequency flyback transformer using FEM technique, a novel and simple approach for its design improvement and loss reduction is introduced. It is shown that leakage flux scattering i...

متن کامل

بررسی روش های تشخیص خطای ترانسفورماتور

power transformers are important equipments in power systems. thus there is a large number of researches devoted of power transformers. however, there is still a demand for future investigations, especially in the field of diagnosis of transformer failures. in order to fulfill the demand, the first part reports a study case in which four main types of failures on the active part are investigate...

Frequency Response Analysis in Power Transformer for Detection of Winding Short-circuit using Quasi-static Finite Element and Circuit-based Method

Detecting and removing minor faults in power transformer winding is essential because minor faults may develop and lead to major faults and finally irretrievable damages occur. In this paper in order to detect the position of short-circuit in the winding, frequency response of the input impedance of a power transformer is analyzed. Common short-circuits are categorized and the results are compa...

متن کامل

Comparison of Impulse Wave and Sweep Frequency Response Analysis Methods for Diagnosis of Transformer Winding Faults

Monitoring of winding faults is the most important item used to determine the maintenance status of a transformer. Commonly used methods for winding-fault diagnosis require the transformer to exit operation before testing and an external exciting signal, whether the transformer is malfunctioning or not. However, if an overvoltage signal can be regarded as a broadband excitation source for fault...