A novel method to correct for pitch and yaw patient setup errors in helical tomotherapy
نویسندگان
چکیده
منابع مشابه
A novel method to correct for pitch and yaw patient setup errors in helical tomotherapy.
An accurate means of determining and correcting for daily patient setup errors is important to the cancer outcome in radiotherapy. While many tools have been developed to detect setup errors, difficulty may arise in accurately adjusting the patient to account for the rotational error components. A novel, automated method to correct for rotational patient setup errors in helical tomotherapy is p...
متن کاملA novel setup approach for helical tomotherapy in head and neck cancer: A case report
Head and neck cancers that are associated with high-risk factors have a poor prognosis. In such patients, post-operative radiochemotherapy is mandatory. The present study describes the case of a 71-year-old high-risk head and neck cancer patient who was not able to tolerate the supine position for the radiotherapy setup. A lateral immobilization with a head mask and a vacuum cushion was perform...
متن کاملA Simulation Study on Patient Setup Errors in External Beam Radiotherapy Using an Anthropomorphic 4D Phantom
Introduction Patient set-up optimization is required in radiotherapy to fill the accuracy gap between personalized treatment planning and uncertainties in the irradiation set-up. In this study, we aimed to develop a new method based on neural network to estimate patient geometrical setup using 4-dimensional (4D) XCAT anthropomorphic phantom. Materials and Methods To access 4D modeling of motion...
متن کاملpassivity in waiting for godot and endgame: a psychoanalytic reading
this study intends to investigate samuel beckett’s waiting for godot and endgame under the lacanian psychoanalysis. it begins by explaining the most important concepts of lacanian psychoanalysis. the beckettian characters are studied regarding their state of unconscious, and not the state of consciousness as is common in most beckett studies. according to lacan, language plays the sole role in ...
Statistical validation of a new helical tomotherapy patient transfer station
The purpose of this work is to evaluate statistically the accuracy of a patient transfer station (PTS, TomoTherapy Inc., Madison, WI) that automatically converts one planning-station-generated treatment plan to another one with a different beam model. In our department we have installed 2 HI*ART tomotherapy systems, and patients often need to be transferred from one tomotherapy unit to the othe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Medical Physics
سال: 2005
ISSN: 0094-2405