A Novel Method for Quantum Yield Measurement of Luminescent Materials Using Integrating Sphere and Thermopile.
نویسندگان
چکیده
منابع مشابه
Measurement of the Fluorescence Quantum Yield Using a Spectrometer With an Integrating Sphere Detector
A method is proposed for measuring the fluorescence quantum yield (QY) using a commercial spectrophotometer with a 150 mm integrating sphere (IS) detector. The IS detector is equipped with an internal cuvette holder so that absorbance measurements can be performed with the cuvette inside the IS. In addition, the spectrophotometer has a cuvette holder outside the IS for performing conventional a...
متن کاملdevelopment of different optical methods for determination of glucose using cadmium telluride quantum dots and silver nanoparticles
a simple, rapid and low-cost scanner spectroscopy method for the glucose determination by utilizing glucose oxidase and cdte/tga quantum dots as chromoionophore has been described. the detection was based on the combination of the glucose enzymatic reaction and the quenching effect of h2o2 on the cdte quantum dots (qds) photoluminescence.in this study glucose was determined by utilizing glucose...
A Novel Method for Human Astigmatism Formulation and Measurement
Astigmatism’s defect has not yet been formulated in Physics and medical physics books theoretically. In this paper, we are trying to formulate the astigmatism’s defect. The results of formulation show that “the degree of astigmatism is negative reverse the distance that vision’s condition of astigmatism’s chart lines change conditions in dimness angle from dimness condition at infinite distance...
متن کاملA Novel Method for Human Astigmatism Formulation and Measurement
Astigmatism’s defect has not yet been formulated in Physics and medical physics books theoretically. In this paper, we are trying to formulate the astigmatism’s defect. The results of formulation show that “the degree of astigmatism is negative reverse the distance that vision’s condition of astigmatism’s chart lines change conditions in dimness angle from dimness condition at infinite distance...
متن کاملMeasuring Fluorescence Quantum Yield Using a Tube Inside an Integrating Sphere
A method for measuring the fluorescence quantum yield Φf of samples using a soft transparent tube with 0.58 mm inner diameter inside an integrating sphere is presented. Based on simple energy balance within the sphere, an equation for determining Φf in terms of the optical output signal is derived. In order to determine the feasibility of measuring Φf using the present integrating sphere-spectr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Review of Laser Engineering
سال: 1997
ISSN: 0387-0200,1349-6603
DOI: 10.2184/lsj.25.171