A novel ion- selective electrode sensor based on crafted polymer sugar thia crown ether for the determination of Cadmium (II)

نویسندگان

چکیده

A Cadmium (II) ion-selective electrode (ISE) based on Thia polymeric crown ether (SPCE-Cd2+) as a membrane carrier in PVC matrix was successfully built for the determination of Cd2+ ions. Using Dimethyl phthalate (DMP) plasticizer, showed Nernstian liner response spanning range 1*10-1 to 1*10-7 M with slope (28) ±2 mV per decade charge and detection limit 1*10-9 M. The sensor has 10-second time. cadmium is highly precise its selectivity over other cations. Some alkali transition metal ions have coefficients 1 * 10-7 10-1. It worked well an indicator potentiometric measurement ion.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sn (II) Ion- Selective Membrane Electrode based on Dibenzo-18-Crown-6

We found that dibenzo-18-crown-6 (DB18C6) can be used as an ionophore to make a tin (II)-ionselectivemembrane electrode. The electrode exhibits a near Nernstian response for Sn2+ ions over aconcentration range from 1.0× 10-6 – 1.0× 10-2 M with a slope of 27.5 ± 0.6 mV per concentration decadein an acidic solution (pH=1). The limit of detection was 8.0× 10-7 M. It has a response time of < 20s an...

متن کامل

An Electrochemical Sensor Based on Novel Ion Imprinted Polymeric Nanoparticles for Selective Detection of Lead Ions

In this study, the novel surface ion-imprinted polymer (IIP) particles were prepared and applied as a electrode modifier in stripping voltammetric detection of lead(II) ion. A carbon paste electrode (CPE) modified with IIP nanoparticles and multi-walled carbon nanotubes (MWCNTs) was used for accumulation of toxic lead ions. Various factors that govern on electrochemical signals including carbon...

متن کامل

Uultra-trace determination of cadmium (II) in aqueous environmental samples by a new ion selective electrode based on nefazodone and 1-butyl-3-methylimidazolium hexafluorophosphate ionic liquid

Background and Objective: Cadmium is a potential environmental contaminant that causes adverse effects on the environment and the health of living organisms. Therefore, designing a simple and economic technique for its determination is very important. In this respect, a potentiometric sensor based on nefazodone as the ionophore and [BMIM]PF6 as the ionic additive were developed for the determin...

متن کامل

sn (ii) ion- selective membrane electrode based on dibenzo-18-crown-6

we found that dibenzo-18-crown-6 (db18c6) can be used as an ionophore to make a tin (ii)-ionselectivemembrane electrode. the electrode exhibits a near nernstian response for sn2+ ions over aconcentration range from 1.0× 10-6 – 1.0× 10-2 m with a slope of 27.5 ± 0.6 mv per concentration decadein an acidic solution (ph=1). the limit of detection was 8.0× 10-7 m. it has a response time of < 20s an...

متن کامل

Selective Membrane Electrode for Bromide Ion Based on Aza Pyrilium Ion Derivative as a new Ionophore.

A highly selective electrode for Bromide ion based on aza pyrilium derivative as an excellentionophore is described.The sensor exhibits a good linear response with a slope of ( 60±1 ) mV per decadeover the concentration range of ( 1×10-3 – 9×10-6 M ) , and a detection limit of ( 3×10-6 M ) of Bromideions .The electrode response is independent of pH in the range of(4.0 –9.5).Selectivity coeffici...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: International Journal of Health Sciences (IJHS)

سال: 2022

ISSN: ['2550-6978', '2550-696X']

DOI: https://doi.org/10.53730/ijhs.v6ns2.5150