A novel high-resolution melting analysis-based method for Yersinia pseudotuberculosis genotyping
نویسندگان
چکیده
منابع مشابه
Development of a High-Resolution Melting Analysis Method for CYP2C19*17 Genotyping in Healthy Volunteers
BACKGROUND Genetic polymorphisms of drug metabolisms by cytochrome P450 (P450s) could affect drug response, attracting particular interest in the pharmacogenetics. Due to the importance of CYP2C19* 17 allele and its capability of super- fast metabolism and also lack of information about distribution of the alleles in Iranian population, this research aimed to use High Resolution Melting (HRM) m...
متن کاملDevelopment of a High-Resolution Melting Method for Screening R188H Polymorphism in XRCC2 Gene
Background: The High Resolution Melting (HRM) method is a new scanning method for detecting unknown changes in DNA and its advantages have persuaded researchers to recruit it as a screening method. Objectives: Here, we developed a HRM method to screen R188H SNP (rs3218536) of XRCC2 and compared the results with a well known PCR-RFLP technique. Materials and Methods: Genomic ...
متن کاملdevelopment of a high-resolution melting analysis method based on sybr green-i for rs7216389 locus genotyping in asthmatic child patients
background: asthma is caused by the combination of different factors. current concepts of asthma pathogenesis emphasize on gene-environment interactions. mega-genome scanning projects revealed that different single nucleotide polymorphisms (snps) are related to asthma susceptibility. rs7216389-t is one of them that is related to childhood asthma and its effect on childhood asthma severity has b...
متن کاملHigh-resolution genotyping by amplicon melting analysis using LCGreen.
BACKGROUND High-resolution amplicon melting analysis was recently introduced as a closed-tube method for genotyping and mutation scanning (Gundry et al. Clin Chem 2003;49:396-406). The technique required a fluorescently labeled primer and was limited to the detection of mutations residing in the melting domain of the labeled primer. Our aim was to develop a closed-tube system for genotyping and...
متن کاملMultiplex amplicon genotyping by high-resolution melting.
High-resolution amplicon melting is a simple method for genotyping that uses only generic PCR primers and a saturating DNA dye. Multiplex amplicon genotyping has previously been reported in a single color, but two instruments were required: a carousel-based rapid cycler and a high-resolution melting instrument for capillaries. Manual transfer of capillaries between instruments and sequential me...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Microbiological Methods
سال: 2012
ISSN: 0167-7012
DOI: 10.1016/j.mimet.2012.09.006