A single supply biopotential amplifier.

A biopotential amplifier for single supply operation is presented. It uses a Driven Right Leg Circuit (DRL) to drive the patient's body to a DC common mode voltage, centering biopotential signals with respect to the amplifier's input voltage range. This scheme ensures proper range operation when a single power supply is used. The circuit described is especially suited for low consumption, batte...

متن کامل

Design and Development of a Novel EOG Biopotential Amplifier

Electric potentials are generated across the Cornea and Retina of the eyes as a result of the movement of eyeballs within the conductive environment of the skull. This is referred to as the Cornea-Retinal Potential (CRP) and is the source of the Electrooculogram (EOG) signal. Since the occurrence of DC drifts and numerous artifacts along with power-line interference had made the EOG signal quit...

متن کامل

Fully differential cryogenic transistor amplifier

We have constructed a dc-coupled differential amplifier capable of operating in the 4.2 K – 300 K temperature range. The amplifier can be operated at high-bias setting, where it dissipates 5 mW, has noise temperature TN < 0.8 K at 4 k source resistance and >40 MHz bandwidth at 4.2 K bath temperature. The bias setting can be adjusted: at our lowest tested setting the amplifier dissipates <100 W,...

متن کامل

Relative Measurement of Differential Electrode Impedance for Contact Monitoring in a Biopotential Amplifier 601 Relative Measurement of Differential Electrode Impedance for Contact Monitoring in a Biopotential Amplifier

In this paper, we propose a simple and relative electrode contact monitoring method. By exploiting the power line interference, which is regarded as one of the worst noise sources for bio-potential measurement, the relative difference in electrode impedance can be measured without a current or voltage source. Substantial benefits, including no extra circuit components, no degradation of the bod...

متن کامل

EE240 Final Project: Design of a fully differential Transconductance Amplifier

We describe a fully differential amplifier for oversampled A/D converter applications. This amplifier employs a single stage telescopic architecture using both N-type and P-type gain-boosting technique with capacitive feedback. This architecture offers extremely high gain, low noise, low power and the need for compensation. But the potential slow-settling problem due to the slow doublet should ...