A Novel Definition of Equivalent Uniform Dose Based on Volume Dose Curve

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reporting and analyzing dose distributions: a concept of equivalent uniform dose.

Modern treatment planning systems for three-dimensional treatment planning provide three-dimensionally accurate dose distributions for each individual patient. These data open up new possibilities for more precise reporting and analysis of doses actually delivered to irradiated organs and volumes of interest. A new method of summarizing and reporting inhomogeneous dose distributions is reported...

متن کامل

Some comments on the concepts of dose and dose equivalent.

Although dose is the simplest and most widely used measurement of a radiation field, it does not always lead to an unambiguous estimate of response. This is reflected in the very wide range of relative biologic effectiveness (RBE) values for biological systems. The ambiguity arises from the focus on energy deposition as the source of biological effect, whether in macroscopic or microscopic volu...

متن کامل

Prescription dose evaluation for APBI with noninvasive image-guided breast brachytherapy using equivalent uniform dose.

PURPOSE Noninvasive image-guided breast brachytherapy (NIBB) is an attractive novel approach to deliver accelerated partial breast irradiation (APBI). Calculations of equivalent uniform dose (EUD) were performed to identify the appropriate APBI dose for this technique. METHODS AND MATERIALS APBI plans were developed for 15 patients: five with three-dimensional conformal APBI (3D-CRT), five wi...

متن کامل

Radiobiological Modeling of Acute Esophagitis Following Radiotherapy of Thorax and Head-Neck Tumors: A Comparison of Lyman Kutcher Burman with Equivalent Uniform Dose-Based Models

Introduction: The current study aimed to compare the performance of radiobiological models in predicting acute esophagitis (AE) complications after three-dimensional conformal radiation therapy (3D-CRT). Material and Methods: Out of a total of 100 patients, 50 patients with concurrent chemotherapy and 50 patients without such therapy wer...

متن کامل

Dose gradient impact on equivalent dose at 2 Gy for high dose rate interstitial brachytherapy

PURPOSE To evaluate a new calculation model estimating the equivalent dose at 2 Gy (EQD2) taking into account dose gradient in high dose rate interstitial brachytherapy (HDRIB). MATERIAL AND METHODS Forty dose-volume histograms (DVHs) of breast (20 pts) and prostate (20 pts) cancer dose distributions were reviewed. Physical prescribed doses (PPD) were 34 Gy (10f/5d) and 18 Gy (6f/2d) for brea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Access

سال: 2019

ISSN: 2169-3536

DOI: 10.1109/access.2019.2905875