A Novel and Simple Maximum Available Gain Equalization Technique for Microwave Amplifiers
نویسندگان
چکیده
منابع مشابه
A Novel Frequency Independent Simultaneous Matching Technique for Power Gain and Linearity in BJT amplifiers
Abstrac—Second-harmonic control is implemented in a balanced common-emitter configuration to facilitate frequency independent third–order intermodulation distortion (IM3) cancellation. Experiments demonstrated an over 15 dB improvement in the output third-order intercept point (OIP3).
متن کاملStability and Gain Prediction of Microwave Tunnel-Diode Reflection Amplifiers
The Nyquist approach to stability is used in a form suitable for representation on a chart having conventional Smith chart scales. It is shown how the gain and stability of negative conductance reflection amplifiers of the tunnel-diode type can be simultaneously predicted on this chart. The technique described is particularly useful in the practical design of these amplifiers embedded in networ...
متن کاملI-4: A Simple and Safe Technique for Varicocele Surgery
s:2127:"Varicocele is the most common pathologic finding in men in infertility study programs and is the most treatable cause of male infertility. Its correction is performed by different surgical techniques, none of which is yet acknowledged as the "gold standard." Some of them, especially the microsurgical ones, are very time consuming and thus expensive; furthermore, all varicocele surgery i...
متن کاملNovel Approach to Design Ultra Wideband Microwave Amplifiers: Normalized Gain Function Method
In this work, we propose a novel approach called “Normalized Gain Function (NGF) method” to design low/medium power single stage ultra wide band microwave amplifiers based on linear S parameters of the active device. Normalized Gain Function TNGF is defined as the ratio of T and |S21|, desired shape or frequency response of the gain function of the amplifier to be designed and the shape of the ...
متن کاملA Novel and Simple Method for HCV Genotyping
Hepatitis C virus (HCV) is a major global health problem and one of the most common causes of chronic liver diseases. The current study was carried out to investigate the ability of High Resolution Melting (HRM) method in HCV genotyping. 40 HCV-Positive sera with unknown and 12 sera with known HCV genotypes were collected from different clinical laboratories in Tehran as well as Rasht in north ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Open Electrical & Electronic Engineering Journal
سال: 2008
ISSN: 1874-1290
DOI: 10.2174/1874129000802010045