A nomogram for deconvolution of single exponential fluorescence decays
نویسندگان
چکیده
منابع مشابه
Fluorescence of crystalline 4-(dimethylamino)benzonitrile. Absence of dual fluorescence and observation of single-exponential fluorescence decays
The fluorescence spectrum of crystals grown from newly synthesized 4-(dimethylamino)benzonitrile (DMABN), measured from 25 down to )112 C, consists of a single emission band originating from a locally excited (LE) state. The fluorescence decay of the DMABN crystals is single exponential at all temperatures investigated. These results show that intramolecular charge transfer (ICT) does not occur...
متن کاملOptimizing Laguerre expansion based deconvolution methods for analysing bi-exponential fluorescence lifetime images.
Fast deconvolution is an essential step to calibrate instrument responses in big fluorescence lifetime imaging microscopy (FLIM) image analysis. This paper examined a computationally effective least squares deconvolution method based on Laguerre expansion (LSD-LE), recently developed for clinical diagnosis applications, and proposed new criteria for selecting Laguerre basis functions (LBFs) wit...
متن کاملSuper-exponential methods for multichannel blind deconvolution
Multichannel blind deconvolution has received increasing attention during the last decade. Recently, Martone [3, 4] extended the super-exponential method proposed by Shalvi and Weinstein [1, 2] for single-channel blind deconvolution to multichannel blind deconvolution. However, the Martone extension suffers from two type of serious drawbacks. The objective of this paper is to obviate these draw...
متن کاملDeconvolution Algorithms for Fluorescence and Electron Microscopy
DECONVOLUTION ALGORITHMS FOR FLUORESCENCE AND ELECTRONMICROSCOPY bySiddharth Shah Chair: Andrew E. Yagle In many imaging applications the image formation process is influenced by thedevice physics of the imaging system. As a result, the image is a distorted version ofthe object. This distortion effect, mathematically modeled as the transfer function,ultimately limits the res...
متن کاملDeconvolution for DCE-MRI using an exponential approximation basis
A deconvolution approach for dynamic contrast enhanced magnetic resonance imaging using an approximation basis of exponential functions constrained to be non-negative and non-increasing is developed and compared with widely used methods. Monotonicity in an exponential basis is implemented in terms of a newly derived condition which is a considerable generalization over a previous condition that...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Biophysical Journal
سال: 1980
ISSN: 0006-3495
DOI: 10.1016/s0006-3495(80)85088-0