A New Synchronous Reference Frame-Based Method for Single-Phase Shunt Active Power Filters
نویسندگان
چکیده
منابع مشابه
A Novel Reference Current Calculation Method for Shunt Active Power Filters using a Recursive Algebraic Approach
This paper presents a novel method to calculate the reference source current and the referencecompensating current for shunt active power filters (SAPFs). This method first calculates theamplitude and phase of the fundamental load current from a recursive algebraic approach blockbefore calculating the displacement power factor. Next, the amplitude of the reference mains currentis computed with ...
متن کاملa novel reference current calculation method for shunt active power filters using a recursive algebraic approach
this paper presents a novel method to calculate the reference source current and the referencecompensating current for shunt active power filters (sapfs). this method first calculates theamplitude and phase of the fundamental load current from a recursive algebraic approach blockbefore calculating the displacement power factor. next, the amplitude of the reference mains currentis computed with ...
متن کاملSynchronous Reference Frame Detection and Hysteresis Control for Active Power Filters
Power Quality means maintaining purely sinusoidal current wave form in phase with a purely sinusoidal voltage wave form throughout in a power system. Due to intensive use of power converters and other non linear loads in industries, an increasing deterioration of the power system voltage and current waveforms has been observed. The most important cause for degrading power quality are harmonic d...
متن کاملSingle-Phase Shunt Active Power Filter Using Indirect Control Method
A single-phase shunt active power filter is used mainly for the elimination of harmonics in single-phase AC networks. In this paper a single-phase shunt active power filter based on, an indirect control technique is designed and simulated. This control technique is achieved by phase shifting the input signal(voltage/current) by π/2.The overall action of the shunt active power filter to eliminat...
متن کاملAdaptive Nonlinear Control of Three-Phase Shunt Active Power Filters
The problem of controlling three-phase shunt active power filters (SAPF) is addressed in presence of nonlinear loads supplied with three-phase power grids. The SAPF-load system is shown to be modeled, in the ( , ) coordinate frame, by a third-order nonlinear state-space representation. The control objective is twofold: (i) compensating for the current harmonics and the reactive power absorbed b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Power Electronics
سال: 2013
ISSN: 1598-2092
DOI: 10.6113/jpe.2013.13.4.692