منابع مشابه
A new optical transducer for arterial pressure measurement.
A new optical pressure transducer system (Viggo) has been assessed and compared with a standard P10 transducer (Spectramed) using a similar 20-gauge cannula, both in vitro in terms of linearity and frequency response and in vivo using an animal model. The linearity of the transducers was comparable; the resonant frequencies were 106 Hz and 75 Hz, respectively. However, the resonant frequency of...
متن کاملSubnanowatt Microbubble Pressure Transducer
We present the first all-Parylene microbubble pressure transducer (μBPT). The μBPT utilizes an electrolytically generated microbubble (μB), trapped in a Parylene microchamber, for pressure sensing. Pressure-induced bubble size variation is detected by electrochemical impedance measurement. Real-time hydrostatic pressure measurement with excellent sensitivity (-10.7 Ω/psi, ±0.1 psi) up to 1.8 ps...
متن کاملA New Vapor Pressure Equation
The Wagner equation for prediction of vapor pressure has been modified in order to improve it accuracy. On the basis of this modifications, development of a new equation for prediction of vapor pressure is outlined. Examples of the use of the equation for obtaining vapor pressure for a total of 94 pure substance are given. The proposed equation combines simplicity and accuracy and performs as w...
متن کاملThe balanced electromagnetic separation transducer a new bone conduction transducer.
Conventional bone conduction transducers, which are relatively large, suffer from poor performance at low frequencies. A new type of electro-dynamic transducer, the balanced electromagnetic separation transducer (BEST), was developed to improve the performance of the conventional transducers. By using a balanced suspension principle, the quadratic distortion forces, as well as the static forces...
متن کاملMeasurement of intracompartmental pressure with use of a new electronic transducer-tipped catheter system.
Laboratory and clinical tests were carried out to determine the clinical usefulness, validity, and safety of a new self-calibrating, battery-powered monitoring system for the measurement of intramuscular pressure with use of an electronic transducer-tipped catheter. The eight probes accurately recorded applied pressures ranging from zero to 160 millimeters of mercury (zero to 21.33 kilopascals)...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Computer Applications
سال: 2016
ISSN: 0975-8887
DOI: 10.5120/ijca2016912490