A new non-contact optical device for ocular biometry.

BACKGROUND A new commercially available device (IOLMaster, Zeiss Instruments) provides high resolution non-contact measurements of axial length (using partial coherent interferometry), anterior chamber depth, and corneal radius (using image analysis). The study evaluates the validity and repeatability of these measurements and compares the findings with those obtained from instrumentation curre...

متن کامل

CLINICAL SCIENCE A new non-contact optical device for ocular biometry

Background: A new commercially available device (IOLMaster, Zeiss Instruments) provides high resolution non-contact measurements of axial length (using partial coherent interferometry), anterior chamber depth, and corneal radius (using image analysis). The study evaluates the validity and repeatability of these measurements and compares the findings with those obtained from instrumentation curr...

متن کامل

Refractive Results Using a New Optical Biometry Device

The aim of the study was to compare the measurements of optical (AL-Scan; Nidek Co., Ltd.) and ultrasonic (Echo Scan US-800; Nidek Co., Ltd.) biometry devices and to assess refractive results after cataract surgery. Eighty-one cataractous eyes of 81 patients were included in this study. Biometry was performed using the AL-Scan and an ultrasonic biometer (USB). Axial length (AL), keratometry (K)...

متن کامل

Biometry and intraocular lens power calculation results with a new optical biometry device: comparison with the gold standard.

PURPOSE To evaluate the agreement in axial length (AL), keratometry (K), anterior chamber depth (ACD) measurements; intraocular lens (IOL) power calculations; and predictability using a new partial coherence interferometry (PCI) optical biometer (AL-Scan) and a reference (gold standard) PCI optical biometer (IOLMaster 500). SETTING Service d'Ophtalmologie, Hopital Bicêtre, APHP Université, Pa...

متن کامل

Nonhuman Primate Ocular Biometry

PURPOSE To examine ocular growth in nonhuman primates (NHPs) from measurements on ex vivo eyes. METHODS We obtained NHP eyes from animals that had been killed as part of other studies or because of health-related issues. Digital calipers were used to measure the horizontal, vertical, and anteroposterior globe diameters as well as corneal horizontal and vertical diameters of excised globes fro...