A new mirrored laryngoscope for difficult intubation
نویسندگان
چکیده
منابع مشابه
Pediatric video laryngoscope rescue for a difficult neonatal intubation.
Management of the airway in neonatal patients with craniofacial abnormalities or facial dysmorphism presents a challenge to health care providers. These patients may require specialized equipment and techniques to secure the airway safely. Video laryngoscopy with standard pediatric sized blades is a newly available and emerging technology and may serve as another tool when a potentially difficu...
متن کاملglidescope video laryngoscope for difficult intubation in emergency patients: a quasi-randomized controlled trial
macintosh direct laryngoscope has been the most widely used device for tracheal intubation. glidescope video laryngoscope (gvl) has been recently introduced as an alternative device for performing intubation; however, its validity in emergency settings has not been thoroughly evaluated. the aim of this study was to compare macintosh direct laryngoscope versus gvl for emergency endotracheal intu...
متن کاملA new tracheal tube for difficult intubation.
We have compared a new Portex tracheal tube with the Oxford tube in performing simulated grade 3 difficult intubations. The Portex tube was modified so that the bevel faced backwards, as in the Oxford tube. A gum elastic introducer was used with both tubes. The time taken and number of attempts needed were recorded, with changes in arterial pressure, heart rate and incidence of sore throat. Bot...
متن کاملCervical Spine Movement and Ease of Intubation Using Truview or McCoy Laryngoscope in Difficult Intubation.
STUDY DESIGN Prospective, observational, analytical, randomized control trial. OBJECTIVE To compare cervical spine movement for best laryngoscopic view and ease of intubation using Truview or McCoy laryngoscope in anticipated difficult intubation. SUMMARY OF BACKGROUND DATA The addition of modified laryngoscope blade to the anesthesiologist's armamentarium adds flexibility and improves the ...
متن کاملGlideScope Video Laryngoscope for Difficult Intubation in Emergency Patients: a Quasi-Randomized Controlled Trial.
Macintosh direct laryngoscope has been the most widely used device for tracheal intubation. GlideScope video laryngoscope (GVL) has been recently introduced as an alternative device for performing intubation; however, its validity in emergency settings has not been thoroughly evaluated. The aim of this study was to compare Macintosh direct laryngoscope versus GVL for emergency endotracheal intu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Anaesthesia
سال: 2002
ISSN: 0003-2409
DOI: 10.1046/j.1365-2044.2002.t01-4-02963.x