A new method of measuring cardiac output in man using lithium dilution.
We describe a new indicator dilution method of measuring cardiac output in man. A bolus injection of lithium chloride 0.6 mmol was given via a central venous catheter and arterial plasma [Li+] recorded using a specially developed sensor incorporating an Li(+)-selective electrode. Cardiac output was derived from the lithium dilution curve, with a correction for packed cell volume. Lithium diluti...
متن کاملNew method of cardiac output measurement using ultrasound velocity dilution in rats.
The aim of this study was to validate a new technique for the measurement of cardiac output (CO) based on ultrasound and dilution (COUD) in anesthetized rats. A transit time ultrasound (TTU) probe was placed around the rat carotid artery, and ultrasound velocity dilution curves were generated on intravenous injections of saline. CO by COUD were calculated from the dilution curves for normal and...
متن کاملFiberoptic-Dye Dilution Method for Measurement of Cardiac Output
A new method for the measurement of cardiac output has been tested in 69 patients undergoing catheterization of the right and left sides of the heart. It is based on the recently described fiberoptic hemoreflection method. In order to verify the validity of these measurements, correlations with stroke indices determined by the Fick principle and by biplane angiocardiography were also carried ou...
متن کاملMeasuring cardiac output: intermittent bolus thermodilution method.
cialist in the cardiac care unit and cardiac observation unit at UCLA Medical Center and is an assistant professor of nursing at the UCLA School of Nursing, Los Angeles, Calif. by a computer and converted into a measurement of cardiac output. Cardiac output is inversely proportional to the area under the curve. The normal cardiac output curve has a rapid smooth upstroke and a gradual downstroke...
متن کاملContinuous cardiac output monitoring with pulse contour analysis: a comparison with lithium indicator dilution cardiac output measurement.
OBJECTIVE Pulse contour analysis can be used to provide beat-to-beat cardiac output (CO) measurement. The current study sought to evaluate this technique by comparing its results with lithium dilution CO (LiCO) measurements. DESIGN Prospective, observational study. SETTING Surgical intensive care unit. PATIENTS Twenty-two patients after cardiac or major noncardiac surgery. MEASUREMENTS ...