Presenting a New Method Based on Branch Placement for Optimal Placement of Phasor Measurement Units
In this paper, a new method based on branch placement for the optimal positioning of Phasor Measurement Units (PMUs) in power systems is proposed. In this method, the PMUs are in type of single-channel and are installed at the beginning of the branches. Therefore, they are able to measure the bus voltages. Also, the installation of the PMUs on the branches increases the security of observabilit...
متن کاملA MULTISTAGE EXPANSION PLANNING METHOD FOR OPTIMAL SUBSTATION PLACEMENT
Optimal distribution substation placement is one of the major components of optimal distribution system planning projects. In this paper optimal substation placement problem is solved using Imperialist Competitive Algorithm (ICA) as a new developed heuristic optimization algorithm. This procedure gives the optimal size, site and installation time of medium voltage substation, using their relate...
متن کاملpresenting a new method based on branch placement for optimal placement of phasor measurement units
in this paper, a new method based on branch placement for the optimal positioning of phasor measurement units (pmus) in power systems is proposed. in this method, the pmus are in type of single-channel and are installed at the beginning of the branches. therefore, they are able to measure the bus voltages. also, the installation of the pmus on the branches increases the security of observabilit...
متن کاملA graph search algorithm: Optimal placement of passive harmonic filters in a power system
The harmonic in distribution systems becomes an important problem due to an increase in nonlinear loads. This paper presents a new approach based on a graph algorithm for optimum placement of passive harmonic filters in a multi-bus system, which suffers from harmonic current sources. The objective of this paper is to minimize the network loss, the cost of the filter and the total harmonic disto...
متن کاملOptimal Current Meter Placement for Accurate Fault Location Purpose using Dynamic Time Warping
This paper presents a fault location technique for transmission lines with minimum current measurement. This algorithm investigates proper current ratios for fault location problem based on thevenin theory in faulty power networks and calculation of short circuit currents in each branch. These current ratios are extracted regarding lowest sensitivity on thevenin impedance variations of the netw...