A NEW IRRADIATION TECHNIQUE USING TWIN-WEDGE FILTERS FOR TANGENTIAL BREAST TREATMENT : OPTIMIZA TION OF DOSE DISTRIBUTION BY THE TWIN-WEDGE-FIELD TECHNIQUE

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of Setup Errors on Dose Distribution for Tangential Wedge Field and Field-in-Field Techniques During Breast Irradiation

This study is aimed to evaluate the effects of setup errors on dose distribution for target volume and healthy tissue within the irradiated volume and also critical surrounding organs for breast radiotherapy (RT) using both the tangential field and the field-in-field (FIF) technique. Ten patients with breast cancer were enrolled. For each patients two plans were generated; tangential field plan...

متن کامل

Optimum reckoning of contra lateral breast dose using physical wedge and enhanced dynamic wedge in radiotherapy treatment planning system

Background: It was intended to investigate the effect of physical wedge (PW) and enhanced dynamic wedges (EDW) on contralateral breast dose during primary breast irradiation in radiotherapy treatment, using high energy photon beams. Materials and Methods: The Varian’s Clinac dual mode linear accelerator model 2100 C/D and Siemen’s Primus accelerators were used for radiation doses wi...

متن کامل

Performance evaluation of field-in-field technique for tangential breast irradiation.

Conventional hard or dynamic wedge systems are commonly applied to reduce the dose inhomogeneity associated with whole breast irradiation. We evaluated the dosimetric benefits of the field-in-field (FIF) technique by comparing it with the electronic compensator (EC), Varian enhanced dynamic wedge (EW) and conventional hard wedge (HW) techniques. Data were obtained from 12 patients who had under...

متن کامل

Tangent field technique of TomoDirect improves dose distribution for whole‐breast irradiation

TomoDirect (TD) is an intensity-modulated radiotherapy system that uses a fixed gantry angle instead of rotational beam delivery. Here, we investigated the effect of the multiple beam technique of TomoDirect on dose distribution compared with commonly-used tangential beams. We included 45 consecutive patients with right breast cancer who underwent postoperative radiotherapy in our institute in ...

متن کامل

Impact of respiratory motion on breast tangential radiotherapy using the field-in-field technique compared to irradiation using physical wedges

BACKGROUND This study aimed to evaluate whether the field-in-field (FIF) technique was more vulnerable to the impact of respiratory motion than irradiation using physical wedges (PWs). PATIENTS AND METHODS Ten patients with early stage breast cancer were enrolled. Computed tomography (CT) was performed during free breathing (FB). After the FB-CT data set acquisition, 2 additional CT scans wer...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Japanese Journal of Radiological Technology

سال: 1991

ISSN: 0369-4305,1881-4883

DOI: 10.6009/jjrt.kj00003322724