A New Feed-forward Compensation Inverter Control Strategy
نویسندگان
چکیده
منابع مشابه
Feed-Forward Control in Half-Bridge Resonant DC Link Inverter
This paper proposes a feed-forward control in a halfbridge resonant dc link inverter. The configuration of feed-forward control is based on synchronous sigma-delta modulation and the halfbridge resonant dc link inverter consists of two inductors, one capacitor and two power switches. The simulation results show the proposed technique can reject non-ideal dc bus improving the total harmonic dist...
متن کاملAdaptive Feed-Forward Cancellation Control of a Full-Bridge DC-AC Voltage Inverter
Dc-ac inverters are needed in many applications. The full-bridge dc-ac inverter has been widely used in industry applications and trough the literature. If the nature of the load is not known a priori, some considerations should be taken in order to assure the quality of service to be provided by the inverter. When nonlinear loads are fed by a full-bridge dc-ac inverter, odd harmonics of the fu...
متن کاملA New Method for Time-Delay Compensation in Control Systems
In this paper a new method is introduced and investigated for removing the destabilizing effects of time-delay parameter in control loops. The concept of the method is taken from the knowledge concerning the dynamic behaviour of irrational transfer functions (Ir-TF), which is discussed and investigated elswhere in frequency response domain and is explained briefly here. Ir-TFs, which are we...
متن کاملA Low-complexity Feed-forward I/Q Imbalance Compensation Algorithm
This paper presents a low-complexity adaptive feedforward I/Q imbalance compensation algorithm. The feed-forward solution has guaranteed stability. Due to its blind nature the algorithm is easily incorporated into an existing receiver design. The algorithm uses three estimators to obtain the necessary parameters for the I/Q imbalance compensation structure. The algorithm complexity is low due t...
متن کاملA New Proof of FDR Control Based on Forward Filtration
For multiple testing problems, Benjamini and Hochberg (1995) proposed the false discovery rate (FDR) as an alternative to the family-wise error rate (FWER). Since then, researchers have provided many proofs to control the FDR under different assumptions. Storey et al. (2004) showed that the rejection threshold of a BH step-up procedure is a stopping time with respect to the reverse filtration g...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: DEStech Transactions on Engineering and Technology Research
سال: 2017
ISSN: 2475-885X
DOI: 10.12783/dtetr/icvmee2017/14644