منابع مشابه
Radiation dose to the nuclear medicine nurses
Background: People who have been administrated radiopharmaceuticals could be a source of radiation to their relatives, medical nurses, and people who are in contact with them. The aim of this work was to estimate radiation dose received by nuclear medicine nurses. Materials and Methods: In this study, the dose rates at various distances of 5 – 100 cm from 70 patients, who were administered diag...
متن کاملNew techniques in nuclear medicine for tumor detection [Persian]
Widespread studies on tumor diagnosis has led to the development of techniques with greater sensitivity and improved specificity for detection of occult and small subclinical tumors. Tumor imaging by radiolabeling of tumor-specific antibodies (Immunoscintigraphy) or tissue specific biochemical agents (Receptor imaging) and especially physiologic imaging with positron emitters (PET), have ...
متن کاملThe new direction of nuclear medicine
The role of the nuclear medicine has changed, from the early days when it was the only alternative to x-rays, to the present, when nuclear images are interpreted in light of specific metabolic processes, not anatomy. The development of specific receptor targeting radiopharmaceuticals, markers of viability using PETor SPECT, analogues of neurotransmitters etc., have placed the nuclear medi...
متن کاملAssessment of radiation dose in nuclear medicine hot lab
Background: Hot lab is a specially designed room in a nuclear medicine hospital where the radiopharmaceuticals are delivered, stored and prepared for dispensing. 99Mo/99mTc-generator is the major source in the hot lab used for various medical imaging. It is important to maintain a standard for hot lab procedures to optimize the patient care and minimize radiation exposure to all nuclear medicin...
متن کاملPatient dose calculation software in nuclear medicine [Persian]
Introduction: Radioactive materials deliver internal radiation dose to patients in nuclear medicine. Manual internal radiation dose assessment is a complicated method. Introduction of a simple dose calculation software is the main goal of the present study. Methods: Using the best current data in internal dose calculation (S-Factors) recommended by ICRP and by cons...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: American Journal of Roentgenology
سال: 1971
ISSN: 0361-803X,1546-3141
DOI: 10.2214/ajr.111.2.405