A New Differential Capacitance Manometer
نویسندگان
چکیده
منابع مشابه
A Combination Simple Manometer and Constant Volume Differential Manometer for Studies in Metabolism
The purpose of this article is to describe a manometer which we have developed during the past year for studies in metabolism and which appears to include a number of features of wide-spread use and interest. It is a combination manometer, offering in a single apparatus the possibilities of either direct or differential manometric measurements. For direct measurements it is the equivalent of tw...
متن کاملHigh-speed microfluidic differential manometer for cellular-scale hydrodynamics.
We propose a broadly applicable high-speed microfluidic approach for measuring dynamical pressure-drop variations along a micrometer-sized channel and illustrate the potential of the technique by presenting measurements of the additional pressure drop produced at the scale of individual flowing cells. The influence of drug-modified mechanical properties of the cell membrane is shown. Finally, s...
متن کاملA systematic interpretation of differential capacitance data
Keith Promislow† Department of Mathematics, Michigan State University, East Lansing, MI Abstract Differential capacitance (DC) data has been widely used to characterize the structure of electrolyte solutions near charged interfaces and as experimental validation of models for electrolyte structure. Fixing a large class of models of electrolyte free energy that incorporate finite volume effects,...
متن کاملNew Floating Capacitance Multipliers
In this paper, a technique for realizing a floating capacitance multiplier based on the use of dual output current conveyors and grounded capacitance is proposed. Its multiplication factor can be tuned by changing the ratio of resistors. Moreover, the circuit is easily modified to electronically tunable floating capacitance multiplier by using current controlled conveyor. Simulation results are...
متن کاملNegative differential capacitance of quantum dots
The dependence of charges accumulated on a quantum dot under an external voltage bias is studied. The charge is sensitive to the changes of number of filled levels and the number of conducting levels ~channels!. We clarify that there are two possible outcomes of applying a bias. ~a! The number of conducting channels increases, but the number of filled levels decreases. ~b! The number of filled ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nippon kagaku zassi
سال: 1961
ISSN: 0369-5387,2185-0917
DOI: 10.1246/nikkashi1948.82.3_285