A neural network to correct mass flow errors caused by two-phase flow in a digital coriolis mass flowmeter
نویسندگان
چکیده
منابع مشابه
Two-phase Boundary Layer Flow, Heat and Mass Transfer of a Dusty Liquid past a Stretching Sheet with Thermal Radiation
The problem of two-phase MHD boundary layer flow, heat and mass transfer over a stretching sheet with fluid-particle suspension and thermal radiation has been studied. The effect of mass transfer in dusty fluid over a stretching sheet is considered for the first time. The governing equations are reduced to a set of non-linear ordinary differential equations under suitable similarity transforma...
متن کاملA Sub-Optimal Look-Up Table Based on Fuzzy System to Enhance the Reliability of Coriolis Mass Flow Meter
Coriolis mass flow meters are one of the most accurate tools to measure the mass flow in the industry. However, two-phase mode (gas-liquid) may cause severe operating difficulties as well as decreasing certitude in measurement. This paper presents a method based on fuzzy systems to correct the error and improve the reliability of these sensors in the presence of two-phase model fluid. Definite ...
متن کاملFlow Analysis Heat and Mass Transfer in a Room
This reports the study on the flow behaviour, heat transfer and contamination distribution in a room. For this purpose the 3-D incompressible Navier-Stokes equations, energy equation and a mass transfer equation which model the concentration of contamination have been applied. For turbulence simulation the two equation standard k- turbulence model was employed. By means of SIMPLE algorithm the...
متن کاملA Compact Micro Coriolis Mass Flow Sensor with Flow Bypass for a Monopropellant Micro Propulsion System
We have designed, fabricated and tested a micromachined Coriolis flow sensor for the measurement of hydrazine (N2H4) propellant flow in a micro chemical propulsion system (μCPS). The sensor will be used for measurement and characterization of the μCPS in a simulated space vacuum environment. To reach the required flow range a bypass system is integrated. Initial measurements demonstrate an incr...
متن کاملCorrecting a Coriolis Meter for Two Phase Oil & Gas Flow
It is also common for flowmeters to be installed downstream of a two or three phase separator. If the well conditions change or the separator has been incorrectly sized, then it is possible that the oil liquid outlet may have some gas carry under. The effects of gas entrainment on the output of ultrasonic and Coriolis meters has been reported previously [1] [2]. It is already known that gas ent...