A Multiplexed Fluorescent Calcium and NFAT Reporter Gene Assay to Identify GPCR Agonists

نویسندگان

چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Multiplexed Fluorescent Calcium and NFAT Reporter Gene Assay to Identify GPCR Agonists

Intracellular calcium response and resulting calcium signaling to an agonist-GPCR interaction are important for the measurement of compound activity in the GPCR drug development. The increase in cytosol calcium concentration can be measured by the fluorescent calcium indicator dye such as Fluo-4 in a quick assay (in 3-5 minutes) using the fluorescence imaging plate reader. The calcium signaling...

متن کامل

Luciferase Reporter Assay System for Deciphering GPCR Pathways

The G protein coupled receptors (GPCR) represent the target class for nearly half of the current therapeutic drugs and remain to be the focus of drug discovery efforts. The complexity of receptor signaling continues to evolve. It is now known that many GPCRs are coupled to multiple G-proteins, which lead to regulation of respective signaling pathways downstream. Deciphering this receptor coupli...

متن کامل

Gemini, a Bifunctional Enzymatic and Fluorescent Reporter of Gene Expression

BACKGROUND The development of collections of quantitatively characterized standard biological parts should facilitate the engineering of increasingly complex and novel biological systems. The existing enzymatic and fluorescent reporters that are used to characterize biological part functions exhibit strengths and limitations. Combining both enzymatic and fluorescence activities within a single ...

متن کامل

A teleost in vitro reporter gene assay to screen for agonists of the peroxisome proliferator-activated receptors.

Several contaminants detected in aquatic ecosystems are agonists of peroxisome proliferator-activated receptors (PPARs). Peroxisome proliferator-activated receptors interact with the retinoid X receptor (RXR) to activate the transcription of genes that control a variety of physiological functions. We cloned and sequenced partial cDNA fragments of rainbow trout (Oncorhynchus mykiss) PPARalpha an...

متن کامل

A Versatile, Bar-Coded Nuclear Marker/Reporter for Live Cell Fluorescent and Multiplexed High Content Imaging

The screening of large numbers of compounds or siRNAs is a mainstay of both academic and pharmaceutical research. Most screens test those interventions against a single biochemical or cellular output whereas recording multiple complementary outputs may be more biologically relevant. High throughput, multi-channel fluorescence microscopy permits multiple outputs to be quantified in specific cell...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Current Chemical Genomics and Translational Medicine

سال: 2013

ISSN: 2213-9885

DOI: 10.2174/2213988501307010001