A multi-wavelength heterodyne optical zooming method based on double grating interferometer
نویسندگان
چکیده
منابع مشابه
Two-wavelength double heterodyne interferometry using a matched grating technique.
Two-wavelength double heterodyne interferometry is applied for topographic measurements on optically rough target surfaces. A two-wavelength He-Ne laser and a matched grating technique are used to improve system stability and to simplify heterodyne frequency generation.
متن کاملHeterodyne common-path grating interferometer with Littrow configuration.
This paper presents a heterodyne common-path grating interferometer with Littrow configuration (HCGIL). The HCGIL can effectively overcome environmental disturbance effect and the DC offset and the amplitude variation of the measurement signals. Experimental results match well with the HP5529A results for long-range measurements. Results also show that the estimated measurement resolution is 0....
متن کاملSelf Referencing Heterodyne Transient Grating Spectroscopy with Short Wavelength
Heterodyning by a phase stable reference electric field is a well known technique to amplify weak nonlinear signals. For short wavelength, the generation of a reference field in front of the sample is challenging because of a lack of suitable beamsplitters. Here, we use a permanent grating which matches the line spacing of the transient grating for the creation of a phase stable reference field...
متن کاملDouble Grating Interferometer with Variable Lateral Shear
A modified Ronchi interferometer using two identical gratings is described. This instrument is very suitable for the measurement of small, zonal aberrations, since the shear can be changed continuously by rotating one grating with respect to the other, while the direction and magnitude of the tilt between the sheared wavefronts can be varied by adjusting the distances of the two gratings from t...
متن کاملDouble frequency grating lateral shear interferometer.
A simple grating lateral shear interferometer is described that can be made to give simultaneously two interferograms having shear in two orthogonal directions. The shear for the two orthogonal directions is produced in one plane by one double frequency crossed diffraction grating that can easily be produced holographically. Translating the grating sideways causes the irradiance of the interfer...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Physics: Conference Series
سال: 2005
ISSN: 1742-6588,1742-6596
DOI: 10.1088/1742-6596/13/1/028