A Multi-Frame, Megahertz CCD Imager
نویسندگان
چکیده
منابع مشابه
MEM-FLIM, a CCD imager for Fluorescence Lifetime Imaging Microscopy
MEM-FLIM, a CCD imager for use in advanced Fluorescence Lifetime Imaging Microscopy (FLIM) applications is presented. A demodulation frequency of 80MHz is achieved with 4V clock swing with an optimized pixel design. An optional electron-multiplication CCD register using a single-poly electrode structure is included in the imager. Introduction A FLIM system requires an imager that can ‘gate’ the...
متن کاملWide- eld CCD imager for the 6.5m MMT telescope
The conversion of the Multiple Mirror Telescope from six 1.8mmirrors to a single 6.5mmirror will signi cantly increase its capability for imaging. The f/5 con guration will provide a corrected eld of view for imaging that is at and 30 arcminutes in diameter. The image quality in the absence of atmospheric seeing is 0: 1 over the full eld. We are currently designing a camera system to take advan...
متن کاملtight frame approximation for multi-frames and super-frames
در این پایان نامه یک مولد برای چند قاب یا ابر قاب تولید شده تحت عمل نمایش یکانی تصویر برای گروه های شمارش پذیر گسسته بررسی خواهد شد. مثال هایی از این قاب ها چند قاب های گابور، ابرقاب های گابور و قاب هایی برای زیرفضاهای انتقال پایاست. نشان می دهیم که مولد چند قاب تنک نرمال شده (ابرقاب) یکتا وجود دارد به طوری که مینیمم فاصله را از ان دارد. همچنین مسایل مشابه برای قاب های دوگان مطرح شده و برخی ...
15 صفحه اولStroboscope Based Synchronization of Full Frame CCD Sensors
The key obstacle to the use of consumer cameras in computer vision and computer graphics applications is the lack of synchronization hardware. We present a stroboscope based synchronization approach for the charge-coupled device (CCD) consumer cameras. The synchronization is realized by first aligning the frames from different video sequences based on the smear dots of the stroboscope, and then...
متن کاملDark signal correction for a lukecold frame-transfer CCD New method and application to the solar imager of the PICARD space mission
Context. Astrophysical observations must be corrected for their imperfections of instrumental origin. When charge-coupled devices (CCDs) are used, their dark signal is one such hindrance. In their pristine state, most CCD pixels are cool, that is, they exhibit a low quasi-uniform dark current, which can be estimated and corrected for. In space, after having been hit by an energetic particle, pi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Nuclear Science
سال: 2009
ISSN: 0018-9499
DOI: 10.1109/tns.2009.2013238