A multi-crystal wavelength dispersive x-ray spectrometer
نویسندگان
چکیده
منابع مشابه
Wavelength-dispersive spectrometer for X-ray microfluorescence analysis at the X-ray microscopy beamline ID21 (ESRF)
The development of a wavelength-dispersive spectrometer for microfluorescence analysis at the X-ray Microscopy ID21 beamline of the European Synchrotron Radiation Facility (ESRF) is reported. The spectrometer is based on a polycapillary optic for X-ray fluorescence collection and is operated in a flat-crystal geometry. The design considerations as well as operation characteristics of the spectr...
متن کاملA multi-cone x-ray imaging Bragg crystal spectrometer.
This article describes a new x-ray imaging Bragg crystal spectrometer, which-in combination with a streak camera or a gated strip detector-can be used for time-resolved measurements of x-ray line spectra at the National Ignition Facility and other high power laser facilities. The main advantage of this instrument is that it produces perfect images of a point source for each wavelength in a sele...
متن کاملDecomposition of Wavelength Dispersive X-Ray Spectra
Line shapes of atomic lines and soft x-ray emission bands measured with a wavelength dispersive spectrometer (WDS) with the Electron Probe Micro Analyzer (EPMA) are reviewed. Least square fitting to pseudo-Voigt profiles of the digitally measured spectra are used to account for the presence of non-diagram features (high and low energy satellites) and instrumental induced distortions. The effect...
متن کاملA simultaneous multiple angle-wavelength dispersive X-ray reflectometer using a bent-twisted polychromator crystal
An X-ray reflectometer has been developed, which can simultaneously measure the whole specular X-ray reflectivity curve with no need for rotation of the sample, detector or monochromator crystal during the measurement. A bent-twisted crystal polychromator is used to realise a convergent X-ray beam which has continuously varying energy E (wavelength λ) and glancing angle α to the sample surface ...
متن کاملOptimization of Wavelength Dispersive X-Ray Spectrometry Analysis Conditions
In setting up the conditions for quantitative wavelength-dispersive electron microprobe analysis a number of parameters have to be defined for each element, namely accelerating voltage, beam current, and (for each element) x-ray line, spectrometer crystal, pulse-height analyser settings, background offsets, and counting times for peak and background. The choices made affect both the reliability...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Review of Scientific Instruments
سال: 2012
ISSN: 0034-6748,1089-7623
DOI: 10.1063/1.4737630