A multi-center output factor intercomparison to uncover systematic inaccuracies in small field dosimetry
نویسندگان
چکیده
منابع مشابه
Reference dosimetry and small - field dosimetry in external beam radiotherapy : Results from a Danish intercomparison study
max. 2000 char.): A comparison of dosimetry methods at different clinics can be used as a means to uncover systematic uncertainties in radiotherapy. To assess the current status of reference dosimetry and small-field dosimetry in clinical practice, a collaborative comparison study involving several dosimetry methods was performed by DTU Nutech at six Danish clinics. The first part of the interc...
متن کاملEnergy and field size dependence of a silicon diode designed for small-field dosimetry
Purpose: To investigate the energy dependence/spectral sensitivity of silicon diodes designed for small-field dosimetry and obtain response factors (RFs) for arbitrary photon spectra using Monte Carlo (MC) simulations. Methods: The EGSnrc user-code DOSRZnrc was used to calculate the dose deposition in water and in the active volume of a stereotactic diode f...
متن کاملA Personal Dosimetry Intercomparison Study in Asian and Pacific Region
The IAEA/RCA (Regional Cooperative Agreement) project to strengthen and harmonize radiation protection infrastructures in Asian and Pacific region started in 1988. The number of the RCA member countries is 17 at present. In the early stages of the project, there was little information on the status of radiation protection and their technical abilities of radiation protection measurements in RCA...
متن کاملDosimetry intercomparison using a 35-keV X-ray synchrotron beam.
The purpose of this study was to compare dose measurements using ion chamber and radiochromic film dosimetry for a 35-keV synchrotron beam useful for Auger electron therapy. A 1.3-GeV electron beam, transported through a 3-pole superconducting wiggler magnet, produced a polychromatic photon beam from which a 35-keV beam (3.3 mm Al HVL) was selected using a monochromator. A 2.8 cm x 2.5 cm field...
متن کاملValidation of a prototype DiodeAir for small field dosimetry.
Standard commercial diode detectors over-respond within small radiation fields, an effect largely attributable to the relatively high mass-density of silicon. However, Monte Carlo studies can be used to optimise dosimeter designs and have demonstrated that 'mass-density compensation'-for example, introducing a low-density air-gap upstream of a diode's high-density silicon volume-can substantial...