A Monte Carlo model for mean glandular dose evaluation in spot compression mammography
نویسندگان
چکیده
منابع مشابه
Evaluation of glandular dose in mammography in the presence of breast cyst using Monte Carlo simulation
Introduction: Average glandular dose (AGD), entrance skin air kerma (ESAK) and normalized glandular dose (DgN) are the main dosimetric quantities in mammography. In this study, DgN is evaluated in the presence of breast cyst, which is a common disease among women and the influence of size, number and location of the cysts on the DgN is investigated. Materials and Meth...
متن کاملCalculation of Absorbed Glandular Dose using a FORTRAN Program Based on Monte Carlo X-ray Spectra in Mammography
Introduction: Average glandular dose calculation in mammography with Mo-Rh target-filter and dose calculation for different situations is accurate and fast. Material and Methods: In this research, first of all, x-ray spectra of a Mo target bombarded by a 28 keV electron beam with and without a Rh filter were calculated using the MCNP code. Then, we used the Sobol-Wu parameters to write a FORTRA...
متن کاملAssessment of mean glandular dose in mammography.
The routine assessment of patient dose in the National Health Service Breast Screening Programme is performed as part of the quality assurance protocol recommended by the Institute of Physical Sciences in Medicine. The mean glandular dose to a standard breast is deduced from measurement of the air kerma at the entrance surface of a 4 cm Perspex phantom by applying a series of conversion factors...
متن کاملEstimation of Mean Estimation of Mean Glandular Dose in Mammography Examination in some of Radiology Centers in Tehran city
Introduction: the objectives of this research were determination of Mean Glandular Dose in film- screen and digital mammography examinations, estimation of accumulated effective dose in some of mammography centers in Tehran city and estimating cancer risk due to these examinations. Materials and Methods: the clinical data were collected from the 1318 <...
متن کاملcalculation of absorbed glandular dose using a fortran program based on monte carlo x-ray spectra in mammography
introduction: average glandular dose calculation in mammography with mo-rh target-filter and dose calculation for different situations is accurate and fast. material and methods: in this research, first of all, x-ray spectra of a mo target bombarded by a 28 kev electron beam with and without a rh filter were calculated using the mcnp code. then, we used the sobol-wu parameters to write a fortra...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Medical Physics
سال: 2017
ISSN: 0094-2405
DOI: 10.1002/mp.12339