A Monte Carlo investigation of the dose distribution for new I-125 Low Dose Rate brachytherapy source in water and in different media

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Monte Carlo Study on the Effect of Various Neutron Capturers on Dose Distribution in Brachytherapy with 252Cf Source

Background: In neutron interaction with matter and reduction of neutron energy due to multiple scatterings to the thermal energy range, increasing the probability of thermal neutron capture by neutron captures makes dose enhancement in the tumors loaded with these materials. Objective: The purpose of this study is to evaluate dose distribution in the presence of 10B, 157Gd and 33S neutron...

متن کامل

Monte Carlo and experimental relative dose determination for an Iridium-192 source in water phantom

Background: Monte Carlo and experimental relative dose determination in a water phantom, due to a high dose rate (HDR) 192Ir source is presented for real energy spectrum and monochromatic at 356 keV. Materials and Methods: The dose distribution has been calculated around the 192Ir located in the center of 30 cm ×30 cm ×30 cm water phantom using MCNP4C code by Monte Carlo method. Relati...

متن کامل

Investigation of dose distribution 252Cf Isotron brachytherapy source based on TG-43U1 protocol by Monte Carlo method

 Introduction:The commercial 252Cf sources are too large in size and clinical applications of neutronbrachytherapy (NBT) are limited to a small number of intracavitary treatments of cervical cancers. Recently, under the Cooperative Research and Development Agreement (CRADA) with Isotron Inc., the Oak Ridge National Laboratory (ORNL) encapsulated a new medical 252Cf sources, cal...

متن کامل

Investigation of dose distribution 252Cf Isotron brachytherapy source based on TG-43U1 protocol by Monte Carlo method.

Introduction: The commercial 252Cf sources are too large in size and clinical applications of neutron brachytherapy (NBT) are limited to a small number of intracavitary treatments of cervical cancers. Recently, under the Cooperative Research and Development Agreement (CRADA) with Isotron Inc., the Oak Ridge National Laboratory (ORNL) encapsulated a new medical 252Cf sources, c...

متن کامل

Study of the absorbed dose rate of all rays emitted from the 252Cf brachytherapy source by the Monte Carlo method

The 252Cf brachytherapy source is a spontaneous fission decay source, which is used as a neutron-emitting source. In addition to neutrons emitted from this source, gamma rays are also emitted with the average energy of 1 MeV. In this study, using the Monte Carlo N-Particle code (MCNPX), the absorbed dose rates of the neutrons, the primary gamma and the secondary gamma that generated by thermal ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Polish Journal of Medical Physics and Engineering

سال: 2019

ISSN: 1898-0309

DOI: 10.2478/pjmpe-2019-0003