A Modified Wire Hanging Apparatus for Small Animal Muscle Function Testing
نویسندگان
چکیده
منابع مشابه
Establishing a new animal model for muscle regeneration studies
Skeletal muscle injuries are one of the most common problems in the worldwide which impose a substantial financial burden to the health care system. Accordingly, it widely accepted that muscle regeneration is a promising approach that can be used to treat muscle injury patients. However, the underlying mechanisms of muscle regeneration have yet to be elucidated. The muscle structure and muscle...
متن کاملA simple anaesthetic apparatus for small animals.
This apparatus was developed for the anaesthesia of small animals, including infant and adult mice, rats, guinea-pigs, rabbits, and rhesus monkeys. The general layout of the apparatus is shown in the diagram. The apparatus consists of an electric pump which drives air through a two-way tap connected to two tubes in an ether container. One of the tubes reaches well below the surface of the ether...
متن کاملA Novel Testing Apparatus for Tribological Studies at the Small Scale
A novel flexure-based biaxial compression/shear apparatus has been designed, built, and utilized to conduct tribological studies of interfaces relevant to MEMS. Aspects of our new apparatus are detailed and its capabilities are demonstrated by an investigation of two interfaces for MEMS applications. Tribological tests may be performed with normal and tangential forces in the μN to N range and ...
متن کاملSiker's Mapleson-modified Boyle apparatus for halothane.
man IR, Yokoyama U, Head BP, Hagiwara Y, Ishikawa Y, Miyanohara A, Patel PM, Insel PA, Patel HH, Roth DM: Cardiac-specific overexpression of caveolin-3 induces endogenous cardiac protection by mimicking ischemic preconditioning. Circulation 2008; 118:1979 – 88 24. Tsutsumi YM, Kawaraguchi Y, Horikawa YT, Niesman IR, Kidd MW, Chin-Lee B, Head BP, Patel PM, Roth DM, Patel HH: Role of caveolin-3 a...
متن کاملModified Lsm for Calibration of Measuring Apparatus
Modified least squares method (LSM) is developed that take into account errors in input standard signals for calibration of measuring devices. Calibration of the differential pressure gage by the standard control-point setting mechanisms is demonstrated in the paper as an example. The accuracy of the coefficient estimates changes when the errors of the control-point setting mechanisms are taken...