A modified rubella HI test using prestandardized reagents.
نویسندگان
چکیده
منابع مشابه
A modified rubella HI test using prestandardized reagents.
A modified haemagglutination inhibition test for rubella antibodies using prestandardized freeze-dried reagents was compared to a "standard" method. Tests of 707 serum samples showed that the modified test was sensitive and reliable by both macrotitration and microtitration techniques. The minor disadvantages of some reduction in antibody level when rubella sera were tested within one week of t...
متن کاملEvaluation of a semiautomated prestandardized immunofluorescence test system for detection of anti-native deoxyribonucleic acid antibodies.
An immunofluorescence-native deoxyribonucleic acid (nDNA) antibody test system (Zeus Scientific, Inc.) was compared with a radioimmunoassay procedure (FARR assay) for detecting anti-nDNA antibodies in human serum. Double-blind studies of split samples obtained from 236 patients showed an 80% correlation between the immunofluorescence-nDNA antibody test system and the radioimmunoassay procedure....
متن کاملModified hemagglutination-inhibition test for rubella employing human group O erythrocytes.
A hemagglutination-inhibition (HI) test for rubella is described which utilizes human group O, rather than 1-day-old chick, erythrocytes. The test was found to be as sensitive and reproducible for detection of rubella antibody as HI tests employing chick erythrocytes. Advantages to the use of human erythrocytes are (i) they are more available, (ii) it is unnecessary to absorb natural agglutinin...
متن کاملDesulfurization of Tabas Coals Using Chemical Reagents
Large reserves of coal in Tabas region of Iran are characterized by low ash and high caking index, suitable for use in metallurgy as coking coal. However, these coals cannot be gainfully utilized because of their high sulfur content. In this work, studies on desulfurization of Tabas coals were carried out in a batch reactor using various reagents. The most effective reagents,<...
متن کاملFalse Positive Rubella Test In Pregnancy
A 28 years female pregnant; 15 week +3 days gestational age, G0, P1, A0; presented for routine antenatal care visit in primary health care center. She had done the investigation in privet hospital showing rubella +ve IgM, CMV +ve IgG. Taking full history, the patient had simple flu like illness several weeks ago with no treatment is needed, no recent contact with a case of rubella nor recent va...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Clinical Pathology
سال: 1976
ISSN: 0021-9746
DOI: 10.1136/jcp.29.12.1101