A Modified Method for Increasing Radiochemical Purity of I-125 for Radiopharmaceuticals

نویسندگان

چکیده

Iodine-125 (125I) is one of the radioisotopes widely used in radiopharmaceuticals for diagnosis and therapy various cancers. Recent reports indicate that there has been shortages world supply this radioiodine isotope. One absolute requirements good must meet radiochemical purity, which generally to be above 95 %, with an efficiency over 90 %. The previous investigation shows purity low does not requirement. In work, we aim at improving method by modifying Jones reductor-based method. modified includes reduction uniformization Zn particle sizes, compaction, performance process a closed flow. reductor converted impurities into products; case, iodate (IO3-) periodate (IO4-) were iodide (I-), so 125I product fulfills yielded high efficiency. investigation, was, first time, improved 99.24 % 97.98

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of Storage Temperature on Radiochemical Purity of 99mTc-Radiopharmaceuticals.

The influence of effective room temperature on the radiochemical purity of 99mTc-radiopharmaceuticals was reported. This study was born from the observation that in the isolators used for the preparation of the 99mTc-radiopharmaceuticals the temperatures can be higher than those reported in the commercial illustrative leaflets of the kits. This is due, in particular, to the small size of the wo...

متن کامل

Altered biodistribution of radiopharmaceuticals: role of radiochemical/pharmaceutical purity, physiological, and pharmacologic factors.

One of the most common problems associated with radiopharmaceuticals is an unanticipated or altered biodistribution, which can have a significant clinical impact on safety, scan interpretation, and diagnostic imaging accuracy. In their most extreme manifestations, unanticipated imaging results may even compromise the utility and or accuracy of nuclear medicine studies. We present here an overal...

متن کامل

Pitfalls in the Standard Radiochemical Purity Testing for Technetium·99m·Exametazime

Objective: The purpose of this study was to examine discrepancies in the standard method for determining the radiochemical purity (RCP) of mTc-exametazime. The package insert for mrc-exametazime indicates that the entire RCP testing procedure requires approximately 15 min to complete, although the solvent-developing time for the three-paper chromatography system is described to be s 1 00 sec. A...

متن کامل

Evaluation of an alternative radiochemical purity testing method for technetium-99m sestamibi.

OBJECTIVE Our study evaluated the accuracy and reliability of 3 radiochemical purity (RCP) measurement methods of 99mTc-sestamibi. A regular-sized (1.0 cm x 9.0 cm) Whatman 31 ET Chr paper strip (regular 31 ET) also was included in our evaluation because of its ease in handling. METHODS The miniaturized and regular 31 ET methods were compared with the standard RCP testing method (aluminum oxi...

متن کامل

An alternative method for determining the radiochemical purity of 99mTc-tetrofosmin.

The instant thin-layer chromatographic method of determining the radiochemical purity of (99m)Tc-tetrofosmin recommended by the manufacturer uses a mixture of acetone and dichloromethane (35:65 v/v) as the solvent and a silica gel (SG) strip as the solid phase. Currently, SG strips are not available commercially and an alternative solid phase is needed. The present study reports that silicic ac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Atom Indonesia

سال: 2023

ISSN: ['0126-1568', '2356-5322']

DOI: https://doi.org/10.55981/aij.2023.1243