A Microprocessor-Controlled Portable Neutron Spectrometer
نویسندگان
چکیده
منابع مشابه
CHELSI: a portable neutron spectrometer for the 20-800 MeV region.
CHELSI is a CsI-based portable spectrometer being developed at Los Alamos National Laboratory for use in high-energy neutron fields. Based on the inherent pulse shape discrimination properties of CsI(Tl), the instrument flags charged particle events produced via neutron-induced spallation events. Scintillation events are processed in real time using digital signal processing and a conservative ...
متن کاملA microprocessor-controlled anaesthetic vaporizer.
A microprocessor-controlled anaesthetic vaporizer is described. Fresh gas is mixed in the correct proportions using two pulsed solenoid valves and a proportion of this passes through a third pulsed solenoid valve and is bubbled through liquid halothane. The temperature of the liquid agent is measured and the pulse frequency is modified to give the correct vapour concentration for the set flow r...
متن کاملSuperheated Drop as a Neutron Spectrometer
Superheated drops are known to vaporise when exposed to energetic nuclear radiation since the discovery of bubble chamber. The application of superheated drops in neutron research specially in neutron dosimetry is a subject of intense research for quite sometime. As the degree of superheat increases in a given liquid, less and less energetic neutrons are required to cause nucleation. This prope...
متن کاملExperiments with a Slow Neutron Velocity Spectrometer
Neutron bursts were produced by modulation of the arc source of a small cyclotron. Neutrons subsequently slowed down in paraffin were detected by a BF3ionization chamber and linear amplifier. Modulation of an additional amplifier allowed the counting of all detected. neutrons as well as those arriving in a specified time interval. Time of flight experiments were carried out at 3.0 meters with "...
متن کاملNIST Calibration of a Neutron Spectrometer ROSPEC
A neutron spectrometer was acquired for use in the measurement of National Institute of Standards and Technology neutron fields. The spectrometer included options for the measurement of low and high energy neutrons, for a total measurement range from 0.01 eV up to 17 MeV. The spectrometer was evaluated in calibration fields and was used to determine the neutron spectrum of an Americium-Berylliu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Nuclear Science
سال: 1980
ISSN: 0018-9499
DOI: 10.1109/tns.1980.4330923