A Micro Gas Flow Meter using Thermistors

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correcting a Coriolis Meter for Two Phase Oil & Gas Flow

It is also common for flowmeters to be installed downstream of a two or three phase separator. If the well conditions change or the separator has been incorrectly sized, then it is possible that the oil liquid outlet may have some gas carry under. The effects of gas entrainment on the output of ultrasonic and Coriolis meters has been reported previously [1] [2]. It is already known that gas ent...

متن کامل

Pressure Drop Measurements in Rectangular Micro - Channel Using Gas Flow

Due to the need for practical cooling technologies which could dissipate high heat fluxes, an experimental study of pressure drop in micro-channel was performed. In this work, laminar flow friction factors were determined using gas (air) as flow medium. Pressure drop vs flow rate data were used to evaluate friction factors in two parallel microchannels, namely MCP1 and MCP2 (1.0 mm deep x 0.240...

متن کامل

Using Burnett Equations to Derive an Analytical Solution to Pressure-Driven Gas Flow and Heat Transfer in Micro-Couette Flow

The aim of the present study is deriving an analytical solution to incompressible thermal flow in a micro-Couette geometry in the presence of a pressure gradient using Burnett equations with first- and second-order slip boundary conditions. The lower plate of the micro-Couette structure is stationary, whereas the upper plate moves at a constant velocity. Non-dimensional axial velocity and tempe...

متن کامل

Compact Mass Flow Meter Based on a Micro Coriolis Flow Sensor

In this paper we demonstrate a compact ready-to-use micro Coriolis mass flow meter. The full scale flow is 1 g/h (for water at a pressure drop < 1 bar). It has a zero stability of 2 mg/h and an accuracy of 0.5% reading for both liquids and gases. The temperature drift between 10 and 50 °C is below 1 mg/h/°C. The meter is robust, has standard fluidic connections and can be read out by means of a...

متن کامل

Flow of Gas Mixtures through Micro Channel

To investigate flow of gas mixtures through micro channel in detail, the tangential momentum accommodation coefficients of each species for gaseous mixtures were determined by analyzing the Couette flow problem of a slightly rarefied gas between two walls. The molecular dynamics (MD) method for the interaction of gas molecule with the wall surface is combined with the DSMC method for the motion...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: SHINKU

سال: 1963

ISSN: 0559-8516,1880-9413

DOI: 10.3131/jvsj.6.141