A Method of Fault Analyses for Power Systems with Superconducting Fault Current Limiters
نویسندگان
چکیده
منابع مشابه
An Optimal Design Approach for Resistive and Inductive Superconducting Fault Current Limiters via MCDM Techniques
The design process of a superconducting current limiter (SFCL) requires simulation and definition of its electrical, magnetic and thermal properties in form of equivalent circuits and mathematical models. However, any change in SFCL parameters: dimension, resistance, and operating temperature can affect the limiting mode, quench time, and restore time. In this paper, following the simulation of...
متن کاملA novel method of flat YBCO rings development for shield-type superconducting fault current limiters fabrication
The application of flat superconductor rings has been investigated in the structure of inductive shieldtype high temperature superconducting fault current limiters, HTc-SFCL. A laboratory scale inductive shield-type HTc-SFCL has been designed and fabricated using flat superconductor rings. The fabrication process has been fully presented. YBCO powder has been used for the fabrication of superco...
متن کاملPower flow analysis and optimal locations of resistive type superconducting fault current limiters
Based on conventional approaches for the integration of resistive-type superconducting fault current limiters (SFCLs) on electric distribution networks, SFCL models largely rely on the insertion of a step or exponential resistance that is determined by a predefined quenching time. In this paper, we expand the scope of the aforementioned models by considering the actual behaviour of an SFCL in t...
متن کاملThe Impact of Superconducting Fault Current Limiter Locations on Voltage Sag in Power Distribution System
In this paper, the impacts of installing superconducting fault current limiter (SFCL)in radial and loop power distribution system are evaluated to improve voltage sag in both cases of with and without distributed generations (DG). Among various SFCLs, the hybrid type with a superconducting element in parallel with a current limiting reactor (CLR) is selected. This is more effective than resisto...
متن کاملFault Current Limiters – Principles and Application
In this paper a new type electrical devices, designed for use in medium voltage and high voltage grids, has been explained – the fault current limiters. Their principals of operation and different structures have been proposed. The comparative analysis and their possibile estimation have been made.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEJ Transactions on Power and Energy
سال: 1993
ISSN: 0385-4213,1348-8147
DOI: 10.1541/ieejpes1990.113.5_543